--	3Com Switching Systems Management Information Base
--	Version 1.0.0
--	February 13, 1998

--	3Com Corporation
--	80 Central Street
--	Boxborough, MA 01719 
--	(508) 264-1400

----------------------------------------------------------------------------------------
--
--  03/09/98 - bbm      Added a3ComSysBridgePortReceiveMulticastLimitMultiplier.
--  02/26/98 - eah      Added port1000NotPresent.
--  02/13/98 - iwolf    Originally created
--
----------------------------------------------------------------------------------------

A3COM-SWITCHING-SYSTEMS-MIB DEFINITIONS ::= BEGIN

IMPORTS
	enterprises, Counter, Gauge, IpAddress FROM RFC1155-SMI
	DisplayString                          FROM RFC1213-MIB
	OBJECT-TYPE                            FROM RFC-1212
	TRAP-TYPE                              FROM RFC-1215;


-- Textual conventions

RowStatus ::= INTEGER {

		-- the following two values are states:
		-- these values may be read or written
		active(1),
		notInService(2),

		-- the following value is a state:
		-- this value may be read, but not written
		notReady(3),

		-- the following three values are
		-- actions: these values may be written,
		--   but are never read
		createAndGo(4),
		createAndWait(5),
		destroy(6)
		}


-- Switching Systems Storage Type

A3ComSysStorageType ::= INTEGER (1..3)
		--storageTypeUnknown(1), (not settable)
   		--storageNonVolatileMemory(2),
    	--storageFlashMemory(3)

-- Switching Systems Address Type

A3ComSysAddressType ::= INTEGER ( 1..2 )
   		--addrTypeUnknown(1), (not settable)
   		--addrIp(2)

-- Switching Systems Resource Type

A3ComSysResourceType ::= INTEGER ( 1..3 )
   		--resourceTypeUnknown(1), (not settable)
   		--resourceSystem(2)
	 	--resourceBridge(3)


-- Switching Systems Resource Bit Mask
--
-- This type represents a variable length bit mask 
-- encoded as an octet string in which the bits are 
-- numbered from left-to-right.
--
-- Example: For an octet string with a length of 4:
--
--                Byte 0    Byte 1    Byte 2    Byte 3
-- Bits:         76543210  76543210  76543210  76543210
-- 
-- Bit String Indices:
--
--           Byte         Bit         Index
--           ====         ====        =====
--            0            7            1
--            0            6            2
--            0            5            3
--            .            .            .
--            .            .            .
--            1            7            9
--            1            6            10
--            1            5            11
--            .            .            .
--            .            .            .
--            4            7            25
--            4            6            26
--            4            5            27
--            .            .            .
--            .            .            .

A3ComSysResourceBitMask ::= OCTET STRING (SIZE(4))


IpxNetworkNumber ::= OCTET STRING (SIZE(4))

ATNetworkNumber ::=
	-- 2 octets of net number
	-- in network byte order
	OCTET STRING (SIZE (2))

ATName ::=
	-- 0 to 32 octets of AppleTalk
	-- ASCII [Inside AppleTalk]
	OCTET STRING (SIZE (0..32))

DdpNodeAddress ::= 
    -- 2 octets of net number
    -- in network byte order,
    -- 1 octet of node number
	OCTET STRING (SIZE (3))

MacAddress ::=
	-- a 6 octet address in
	-- the "canonical" order
	-- defined by IEEE 802.1a, i.e., as if it were transmitted least
	-- significant bit first
	OCTET STRING (SIZE (6))

--
-- Object identifiers
--
	
a3Com						OBJECT IDENTIFIER ::= { enterprises 43 }

switchingSystems-mib		OBJECT IDENTIFIER ::= { a3Com 29 } 

switchingSystemsMibGroups		OBJECT IDENTIFIER ::= { switchingSystems-mib 4 }
switchingSystemsFddiMibGroups	OBJECT IDENTIFIER ::= { switchingSystems-mib 10 }

-- switchingSystemsMib groups.
 
a3ComSysSystem             OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 1 }
a3ComSysSlot               OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 2 }
a3ComSysControlPanel       OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 3 }
a3ComSysPowerSupply        OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 4 }
a3ComSysSnmp               OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 5 }
a3ComSysAgent              OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 6 }
a3ComSysInterface          OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 7 }
a3ComSysEthernetPort		OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 8 }
a3ComSysSmt				OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 9 }
a3ComSysBridge				OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 10 }
a3ComSysIpRouter			OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 11 }
a3ComSysNetworkMonitor		OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 12 }
a3ComSysTokenRingPort		OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 13 }
a3ComSysFtGroup			OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 14 }
a3ComSysIpGroup            OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 15 }
a3ComSysIpxGroup           OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 16 }
a3ComSysAppleTalkGroup     OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 17 }
a3ComSysModuleCardGroup    OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 18 }
a3ComSysDiagnosticsGroup   OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 19 }



-- The Switching Systems MIB system group.  Implementation of this
-- group is mandatory for agents which manage system resources.

a3ComSysSystemId OBJECT-TYPE
	SYNTAX	INTEGER 
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"The unique identifier assigned to this system during
	manufacturing."
	::= { a3ComSysSystem 1 }

a3ComSysSystemType OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),
		lanplex6000(2),
		lanplex2000(3),
		coreBuilder3500(4),
		coreBuilder9400(5),
		superStack3900(6),
		superStack9300(7)
			}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"The type of system."
	::= { a3ComSysSystem 2 }

a3ComSysSystemName OBJECT-TYPE
	SYNTAX	DisplayString (SIZE (0..31))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"The text string describing this system."
	::= { a3ComSysSystem 3 }

a3ComSysSystemManufacturer OBJECT-TYPE
	SYNTAX	DisplayString (SIZE (0..127))
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"The text string describing the manufacturer of this
	system."
	::= { a3ComSysSystem 4 }

a3ComSysSystemHardwareRevision OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE (2)) 
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"The revision level of the system, contained in two
	octets.  The first octet indicates the artwork revision,
	and the second octet indicates the rework level."
	::= { a3ComSysSystem 5 }

a3ComSysSystemMemorySize OBJECT-TYPE
	SYNTAX	INTEGER 
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"The amount of memory (RAM), in bytes, present on the
	system processor board." 
	::= { a3ComSysSystem 6 }

a3ComSysSystemFlashMemorySize OBJECT-TYPE
	SYNTAX	INTEGER 
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"The amount of flash memory, in bytes, present on the
	system processor board."
	::= { a3ComSysSystem 7 }

a3ComSysSystemNvMemorySize OBJECT-TYPE
	SYNTAX	INTEGER 
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"The amount of non-volatile memory, in bytes, present
	on the system processor board." 
::= { a3ComSysSystem 8 }

a3ComSysSystemSoftwareRevision OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE (4)) 
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"The revision number of the Switching Systems software.
	Each byte indicates the following:
	byte 0: major release number.
	byte 1: minor release number.
	byte 2: update number.
	byte 3:
	bits 7-6: release type.
	bits 5-0: supplemental identifier."
::= { a3ComSysSystem 9 }

a3ComSysSystemBuildTime OBJECT-TYPE
	SYNTAX	DisplayString (SIZE (0..127))
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"The build time of the system software."
	::= { a3ComSysSystem 10 }

a3ComSysSystemSnmpRevision OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"The revision number of the SNMP agent implementation."
	::= { a3ComSysSystem 11 }

a3ComSysSystemRequestedSnmpMode OBJECT-TYPE
	SYNTAX	INTEGER {
		singleAgentMode(1),
		multiAgentMode(2)
			}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
	"This object describes the requested SNMP mode for the
	system.  The value of this object indicates the mode that
	will become effective following a reboot of the system.
	Note that only a subset of the above values may be valid
	for some systems."
	::= { a3ComSysSystem 12 }

a3ComSysSystemCurrentSnmpMode OBJECT-TYPE
	SYNTAX	INTEGER {
		singleAgentMode(1),
		multiAgentMode(2)
			}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"This object describes the currently active SNMP mode for
	the system.  Note that only a subset of the above values
	may be valid for some systems."
	::= { a3ComSysSystem 13 }

a3ComSysSystemAction OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),
		reset(2),
		nvReset(3)
			}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
	"This object, when read, always returns the value other(1). 

	Setting this object to the value reset(2) causes a reset 
	of the system.  

	Setting this object to the value nvReset(3) causes the
	system's non-volatile configuration to be reset to the 
	default values.

	The value other(1) is not a vaild value for set operations."
	::= { a3ComSysSystem 14 }

a3ComSysSystemOvertemperature OBJECT-TYPE
	SYNTAX	INTEGER {
		true(1),
		false(2),
		notSupported(3)
			}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"This object indicates the current overtemperature
	status for the system.  If the system does not support
	overtemperature detection, this object returns
	notSupported."
	::= { a3ComSysSystem 15 }

a3ComSysSystemFanFailure OBJECT-TYPE
	SYNTAX	INTEGER {
		true(1),
		false(2),
		notSupported(3)
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"This object indicates the current fan status for the
	system.  If the system does not support fan failure
	detection, this object returns notSupported."
	::= { a3ComSysSystem 16 }

a3ComSysSystemProtocolMask OBJECT-TYPE
	SYNTAX	INTEGER 
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"This object is a bit mask that indicates which protocols
	 exist in the software image currently loaded in memory.  
	 The value of this OBJECT is a sum.  It initially takes
	 on the value 0, then for each protocol bit as defined
	 below, 2 raised to the value of the (bit position - 1)
	 is added to the sum.

	 The following bits are defined:

		IP_ROUTING	0x00000001
		IPX_ROUTING 0x00000002
		DDP_ROUTING 0x00000004

	 A value of 0x00000000 indicates the
	 standard switching software."
::= { a3ComSysSystem 17 }

a3ComSysSystemConsoleAccess OBJECT-TYPE
	SYNTAX  INTEGER {
		enabled  (1),	--  Console Access is permitted (unlocked)   
		disabled (2)	--  Console Access is prohibited  (locked)
	}
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
	"This object determines whether another device
	can remotely access the system console via Telnet,
	Rlogin, or modem port.

	An existing remote session will not be terminated
	when this value is modified."
::= { a3ComSysSystem 18 }

a3ComSysSystemConsoleReadPwd OBJECT-TYPE
	SYNTAX  DisplayString (SIZE (0..31)) 
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
	"This object is the console read-access password."
::= { a3ComSysSystem 19 }

a3ComSysSystemConsoleWritePwd OBJECT-TYPE
	SYNTAX  DisplayString (SIZE (0..31)) 
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
	"This object is the console write-access password. The
	read-write community string is required for access to this
	object."
::= { a3ComSysSystem 20 }

a3ComSysSystemConsoleAdminPwd OBJECT-TYPE
	SYNTAX  DisplayString (SIZE (0..31)) 
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
	"This object is the console admin-access password. The
	read-write community string is required for access to this
	object."
::= { a3ComSysSystem 21 }


a3ComSysSystemDateTime OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
		"The current date and time as reflected by the 
		system clock in the format mm/dd/yy hh:mm:ss xM."
::= { a3ComSysSystem 22 }

a3ComSysSystemDSTime OBJECT-TYPE
	SYNTAX  INTEGER (-120..120)
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
		"This parameter specifies the displacement, in
		minutes, from non-daylight savings time.  The
		a3ComSysDSTime object, along with the a3ComSysTimeZone
		object, allows the system to support Universal
		time for network communications spanning different
		time zones."
::= { a3ComSysSystem 23 }

a3ComSysSystemTimeZone OBJECT-TYPE
	SYNTAX  INTEGER (-720..720)
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
		"This parameter specifies, in minutes,
		displacement of the system west of Greenwich.
		A negative number for this parameter indicates how
		many minutes displacement east of Greenwich
		the site is located.  A positive number
		indicates the number of minutes west of Greenwich."
::= { a3ComSysSystem 24 }

a3ComSysSystemCurrentFddiStationMode OBJECT-TYPE
	SYNTAX  INTEGER {
		singleStationMode(1),
		multiStationMode(2)
		}
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"This object describes the current FDDI station 
		mode for systems that support multi-station mode."
::= { a3ComSysSystem 25 }

a3ComSysSystemRequestedFddiStationMode OBJECT-TYPE
	SYNTAX  INTEGER {
		singleStationMode(1),
		multiStationMode(2)
		}
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
		"This object describes the requested FDDI station 
		mode for systems that support multi-station mode.
		The requested mode will become current during
		the next system reboot."
::= { a3ComSysSystem 26 }

a3ComSysSystemLog OBJECT IDENTIFIER ::= { a3ComSysSystem 27 }

a3ComSysSystemLogEntryCurrentCount OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The number of entries currently recorded in the system log."
::= { a3ComSysSystemLog 1 }

a3ComSysSystemLogMaxSize OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The maximum number of events that can be recorded in the system log."
	::= { a3ComSysSystemLog 2 }

a3ComSysSystemLogSeverityThreshold OBJECT-TYPE
	SYNTAX INTEGER
	{	informational(1),
		warning(2),
		error(3),
		fatal(4)
	}
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"This object determines the miminum serverety level of events recorded in the
		system log.  For example, if the a3ComSysSysteLogSeverityThreshold is set to errors(3)
		than only events which have serverity levels of error(3) or higher will
		be recorded."
::= { a3ComSysSystemLog 3 }

a3ComSysSystemLogTable OBJECT-TYPE
	SYNTAX SEQUENCE OF A3ComSysSystemLogEntry
	ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
		"This table provides information on recorded system events."
::= { a3ComSysSystemLog 4 }

a3ComSysSystemLogEntry OBJECT-TYPE
	SYNTAX A3ComSysSystemLogEntry
	ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
		"A system log entry."
	INDEX { a3ComSysSystemLogIndex }
::= { a3ComSysSystemLogTable 1 }

A3ComSysSystemLogEntry ::=	SEQUENCE {
	a3ComSysSystemLogIndex 		INTEGER,
	a3ComSysSystemLogSeverityLevel 	INTEGER,
	a3ComSysSystemLogDateTime 		DisplayString,
	a3ComSysSystemLogFacility 		INTEGER,
	a3ComSysSystemLogMessage 		DisplayString 
}

a3ComSysSystemLogIndex OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	"The index of the log entry relative to this entry."
::= { a3ComSysSystemLogEntry 1 }

a3ComSysSystemLogSeverityLevel OBJECT-TYPE
	SYNTAX INTEGER {
		information(1),
		warning(2),
		error(3),
		fatal(4)
	}
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicates the severity level of the log entry."
::= { a3ComSysSystemLogEntry 2 }

a3ComSysSystemLogDateTime OBJECT-TYPE
	SYNTAX DisplayString 
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicates the date and time of the log event and is formatted
		as follows: MM:DD:YY  HH:MM:SS."
	::= { a3ComSysSystemLogEntry 3 }


a3ComSysSystemLogFacility OBJECT-TYPE
	SYNTAX INTEGER
	{
		exception(1),
		operatingSystem(2),
		assertion(3),
		spanningTree(4),
		fcmlmm(5),
		lmmfddi(6),
		lmmboard(7),
		esm(8),
		trsm(9),
		efsm(10),
		fsm(11),
		hsi(12)
	}
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The facility which entered the event in the log.  fcmlmm(6) represents
		those events which may be common to the Lanplex Management Module
		(LMM) and the FDDI Concentrator Module (FCM).  lmmfddi(6) represents
		those events specific to the FDDI portion of the LMM and lmmboard 
		represents general events logged by the LMM." 
::= { a3ComSysSystemLogEntry 4 }

a3ComSysSystemLogMessage OBJECT-TYPE
	SYNTAX DisplayString
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The recorded log message."
::= { a3ComSysSystemLogEntry 5 }

a3ComSysSystemBaseMACAddress OBJECT-TYPE
	SYNTAX  MacAddress
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The base MAC address for the system."
::= { a3ComSysSystem 28 }

a3ComSysSystemMACAddressCount OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The number of MAC addresses allocated to this system."
::= { a3ComSysSystem 29 }

a3ComSysSystemChassisSerialNumber OBJECT-TYPE
	SYNTAX  DisplayString (SIZE(12))
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The serial number of the chassis."
::= { a3ComSysSystem 30 }

a3ComSysSystemFPMemorySize OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The amount of frame processor memory (RAM), in bytes."
::= { a3ComSysSystem 31 }

a3ComSysSystemBufferSize OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The amount of buffer memory, in bytes."
::= { a3ComSysSystem 32 }


-- The Switching Systems MIB slot group.  Implementation of this
-- group is mandatory for agents which manage system resources
-- for systems with independently manageable slots.

a3ComSysSlotCount OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
	"The count of slots in the chassis."
::= { a3ComSysSlot 1 }

-- The Switching Systems MIB slot table.

a3ComSysSlotTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF A3ComSysSlotEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION
			"A list of slot entries.  A single entry exists in this
			list for each slot in the chassis."
::= { a3ComSysSlot 2 }

a3ComSysSlotEntry OBJECT-TYPE
	SYNTAX  A3ComSysSlotEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION
			"A slot entry contains information about a particular
			slot."
	INDEX   { a3ComSysSlotIndex }
::= { a3ComSysSlotTable 1 }

A3ComSysSlotEntry ::=
	SEQUENCE {
		a3ComSysSlotIndex
			INTEGER,
		a3ComSysSlotBoardType
			INTEGER,
		a3ComSysSlotBoardRevision
			OCTET STRING,
		a3ComSysSlotBoardStatus
			INTEGER,
		a3ComSysSlotBoardName
			DisplayString,
		a3ComSysSlotBoardNameAbbrev
			DisplayString,
		a3ComSysSlotEthernetPortCount
			INTEGER,
		a3ComSysSlotFddiMacCount
			INTEGER,
		a3ComSysSlotFddiPortCount
			INTEGER,
		a3ComSysSlotOvertemperature
			INTEGER,
		a3ComSysSlotTokenRingPortCount
			INTEGER,
		a3ComSysSlotBoardRevStr
			DisplayString,
                a3ComSysSlotConverterBad
                    INTEGER
    }

a3ComSysSlotIndex OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The index of the slot identified by this entry."
::= { a3ComSysSlotEntry 1 }

a3ComSysSlotBoardType OBJECT-TYPE
	SYNTAX  INTEGER {
				other(1),
				emptyLocation(2),
				esmBoard(7),
				fcmBoard(8),
				lmmBoard(9),
				efsmBoard(10),
				trsmBoard(11),
				tmmBoard(12),
				fsmBoard(13),
				fesmBoard(14)
			}
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The type of board residing in the slot identified by
			this entry."
::= { a3ComSysSlotEntry 2 }

a3ComSysSlotBoardRevision OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE (0..1))
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The revision number of the board in the slot identified
			by this entry.  If the slot is empty, or the revision is
			unknown this object returns a zero length string."
::= { a3ComSysSlotEntry 3 }

a3ComSysSlotBoardStatus OBJECT-TYPE
	SYNTAX  INTEGER {
				notPresent(1),
				testing(2),
				offline(3),
				online(4)
			}
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The status of the board in the slot identified by this
                    entry."
::= { a3ComSysSlotEntry 4 }

a3ComSysSlotBoardName OBJECT-TYPE
	SYNTAX  DisplayString (SIZE (0..255))
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The text string describing the board in the slot
			identified by this entry."
::= { a3ComSysSlotEntry 5 }

a3ComSysSlotBoardNameAbbrev OBJECT-TYPE
	SYNTAX  DisplayString (SIZE (0..31))
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The abbreviation used to describe the board in the slot
			identified by this entry."
::= { a3ComSysSlotEntry 6 }

a3ComSysSlotEthernetPortCount OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The count of ethernet ports in the slot identified by
			this entry."
::= { a3ComSysSlotEntry 7 }

a3ComSysSlotFddiMacCount OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The count of FDDI MACs in the slot identified by this
			entry."
::= { a3ComSysSlotEntry 8 }

a3ComSysSlotFddiPortCount OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The count of FDDI ports in the slot identified by this
			entry."
::= { a3ComSysSlotEntry 9 }

a3ComSysSlotOvertemperature OBJECT-TYPE
	SYNTAX  INTEGER {
		true(1),
		false(2),
		notSupported(3)
    }
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"This object indicates the current overtemperature status
			for the slot.  If the slot does not support overtemperature
			detection, this object returns notSupported."
::= { a3ComSysSlotEntry 10 }

a3ComSysSlotTokenRingPortCount OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The count of TokenRing ports in the slot identified by this
			entry."
::= { a3ComSysSlotEntry 11 }

a3ComSysSlotBoardRevStr  OBJECT-TYPE
	SYNTAX  DisplayString (SIZE (0..5))
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"This revision number of the board in the slot identified
		by this entry.  If the slot is empty, or the revision is
		unknown this object returns a zero length string.  The
		format of the string is XX.YY, where the XX is the major
		revision (artwork), the YY is the minor revision (rework)"
::= { a3ComSysSlotEntry 12 }

a3ComSysSlotConverterBad OBJECT-TYPE
	SYNTAX  INTEGER {
		true(1),
		false(2),
		notSupported(3)
	}
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"This object indicates the current status +12V->+5V
			converter for the slot.  If the slot does not support
			+12V->+5V converter detection, this object returns
			notSupported."
::= { a3ComSysSlotEntry 13 }


-- The LANplex Systems MIB control panel group.  Implementation of
-- this group is mandatory for agents which manage system resources
-- for systems which are equipped with manageable control panels.

a3ComSysControlPanelHardwareRevision OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE (1))
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"An 8-bit value specifying the revision level of the
			control panel hardware."
::= { a3ComSysControlPanel 1 }

a3ComSysControlPanelSoftwareRevision OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE (1))
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"An 8-bit value specifying the revision level of the
			control panel software."
::= { a3ComSysControlPanel 2 }

a3ComSysControlPanelLines OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The number of lines in the control panel display."
::= { a3ComSysControlPanel 3 }

a3ComSysControlPanelColumns OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The number of columns in the control panel display."
::= { a3ComSysControlPanel 4 }

a3ComSysControlPanelText OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE (0..127))
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The currently displayed text in the control panel
			display."
::= { a3ComSysControlPanel 5 }

a3ComSysControlPanelAccess OBJECT-TYPE
	SYNTAX  INTEGER {
		enabled  (1),   --  Panel Access is permitted (unlocked)
        disabled (2)    --  Panel Access is prohibited (locked)
    }
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
		"This object determines whether modifications to system
		 configuration are allowed via the Control Panel"
::= { a3ComSysControlPanel 6 }


-- The Switching Systems MIB power supply group.  Implementation of this
-- group is mandatory for agents which manage system resources for
-- systems which are equipped with managable power supplies.

a3ComSysPowerSupplyCount OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"The count of power supplies in the system."
::= { a3ComSysPowerSupply 1 }

-- The Switching Systems MIB power supply status table.

a3ComSysPowerSupplyStatusTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysPowerSupplyStatusEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A list of power supply status entries."
::= { a3ComSysPowerSupply 2 }

a3ComSysPowerSupplyStatusEntry OBJECT-TYPE
	SYNTAX	A3ComSysPowerSupplyStatusEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A power supply status entry contains information about a 
			particular power supply."
			INDEX	{ a3ComSysPowerSupplyStatusIndex }
::= { a3ComSysPowerSupplyStatusTable 1 }

A3ComSysPowerSupplyStatusEntry ::=
	SEQUENCE {
		a3ComSysPowerSupplyStatusIndex
			INTEGER,
		a3ComSysPowerSupplyStatus
			INTEGER,
		a3ComSysPowerSupplyStatusSupported
			INTEGER
	}

a3ComSysPowerSupplyStatusIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The unique index of the power supply identified by this
			entry."
::= { a3ComSysPowerSupplyStatusEntry 1 }

a3ComSysPowerSupplyStatus OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"This object represents the power supply status.  The
			value is a sum. It initially takes on the value 0, then
			for each type which is active, 2 raised to a power is
			added to the sum.  The powers are according to the
			following table.
			For the 6000 Backbone Aggregator an over temp for power
			supply 1 and power supply 2 will be reported as a power
			supply 1 Over Temperature Failure, and a fan failure will
			be reported as a power supply 2 Over Temperature Failure.

				Failure Type		      Power
				AC Failure			0
				Plus 5 Failure			1
				Plus 12 Failure			2
				Over Temperature Failure  	3
				Power Supply Inserted		4
						Power Supply Extracted		5"
::= { a3ComSysPowerSupplyStatusEntry 2 }

a3ComSysPowerSupplyStatusSupported OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"This object represents the various power supply status 
			types which are supported.  The value is a sum.  It
			initially takes on the value 0, then for each type
			which is supported, 2 raised to a power is added to the
			sum.  The powers are according to the following table:

				Failure Type		      Power
				AC Failure			0
				Plus 5 Failure			1
				Plus 12 Failure			2
				Over Temperature Failure	3
				Power Supply Inserted		4
				Power Supply Extracted		5

			This object used in conjunction with the
			a3ComSysPowerSupplyStatus object for a given power supply
			provide a complete picture of the status of the power
			supply."
	::= { a3ComSysPowerSupplyStatusEntry 3 }


-- The LANplex Systems MIB SNMP group.  Implementation of this group
-- is mandatory for agents in systems which contain multiple
-- independently manageable devices and which support a multiple agent
-- mode.  Note that this group is only available in the multiple agent
-- mode for those systems that support it.

a3ComSysSnmpAgentId OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The unique id for this SNMP agent within the system."
::= { a3ComSysSnmp 1 }

a3ComSysSnmpInternalAgentTrapMask OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE (8))
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
			"This value is a bit string that indicates which traps
			are enabled for transmit to other agents in the system.
			The octet string value is treated as a 64-bit integer
			value.  The value is a sum.  It initially takes on the
			value 0, then for each trap which is enabled, 2 raised
			to the value of (a3ComSysAgentTrapDescriptionIndex - 1) for
			that trap is added to the sum."
::= { a3ComSysSnmp 2 }

a3ComSysSnmpInternalAgentTrapDestinationMask OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
			"A value which indicates to which other agents in the
			system traps should be sent.  The value is a sum.  It
			initially takes on the value 0, then for each agent which
			is to receive traps, 2 raised to the value of
			(a3ComSysSnmpAgentId - 1) for that agent is added to the sum.
			Note that only traps which are enabled according to the
			value of the a3ComSysSnmpInternalAgentTrapMask object will be
			forwarded, and that each trap which is forwarded will
			be transmitted to each agent identified by this mask."
::= { a3ComSysSnmp 3 }

a3ComSysSnmpProxyInternalRequests OBJECT-TYPE
	SYNTAX  INTEGER {
				true(1),
				false(2)
			}
	ACCESS  read-write
	STATUS  deprecated
	DESCRIPTION
			"This object determines if this agent will proxy requests
			to other agents in the system.  If the value of this
			object is true(1), this agent will proxy requests to other
			agents in the chassis."
::= { a3ComSysSnmp 4 }

a3ComSysSnmpInternalProxyRequestMaxAge OBJECT-TYPE
	SYNTAX  INTEGER (1..255)
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
			"The maximum time, in seconds, an internal proxy request
			will remain queued waiting for a response before being
			discarded.  Note that when the value of
			a3ComSysSnmpProxyInternalRequests is false(2), the value of
			this object is ignored."
::= { a3ComSysSnmp 5 }

a3ComSysSnmpProxyInternalTraps OBJECT-TYPE
	SYNTAX  INTEGER {
				true(1),
				false(2)
			}
	ACCESS  read-write
	STATUS  deprecated
	DESCRIPTION
			"This object determines if this agent will generate proxy
			traps for those traps received from other agents in the
			system.  If the value of this object is true(1), this
			agent will generate proxy traps for those received from
			other agents in the chassis.  Note that agents will not
			proxy traps to other agents within the system to prevent
			looping of traps."
::= { a3ComSysSnmp 6 }


-- The LANplex Systems MIB SNMP internal proxy table.

a3ComSysSnmpInternalProxyTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF A3ComSysSnmpInternalProxyEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION
			"A list of SNMP internal agent proxy entries.  An entry in
			this table exists for each agent in the system that can be
			reached by this agent via the internal proxy mechanism."
::= { a3ComSysSnmp 7 }

a3ComSysSnmpInternalProxyEntry OBJECT-TYPE
	SYNTAX  A3ComSysSnmpInternalProxyEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION
			"An entry identifies the communities available for
			communicating with another agent in the system via the
			internal proxy mechanism."
	INDEX   { a3ComSysSnmpInternalProxyAgentId,
			a3ComSysSnmpInternalProxyAccessClass }
::= { a3ComSysSnmpInternalProxyTable 1 }

A3ComSysSnmpInternalProxyEntry ::=
	SEQUENCE {
		a3ComSysSnmpInternalProxyAgentId
			INTEGER,
		a3ComSysSnmpInternalProxyAccessClass
			INTEGER,
		a3ComSysSnmpInternalProxyCommunity
			OCTET STRING
	}

a3ComSysSnmpInternalProxyAgentId OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The id of the agent identified by this entry."
::= { a3ComSysSnmpInternalProxyEntry 1 }

a3ComSysSnmpInternalProxyAccessClass OBJECT-TYPE
	SYNTAX  INTEGER {
				readOnly(1),
				readWrite(2)
			}
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The access to MIB objects supported by the agent
			identified by this entry provided by this agent, when
			using the community string identified by the corresponding
			value of a3ComSysSnmpInternalProxyCommunity."
::= { a3ComSysSnmpInternalProxyEntry 2 }

a3ComSysSnmpInternalProxyCommunity OBJECT-TYPE
	SYNTAX  OCTET STRING
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"A community which allows access to MIB objects supported
			by the agent identified by this entry."
::= { a3ComSysSnmpInternalProxyEntry 3 }



-- The Switching Systems MIB agent group.  Implementation of this group
-- is mandatory for all agents.

a3ComSysAgentRequestMaxAge OBJECT-TYPE
	SYNTAX	INTEGER (1..255)
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"The maximum time, in seconds, a local SNMP request will
			remain queued waiting for a response before being
			discarded."
::= { a3ComSysAgent 1 }

a3ComSysAgentProxyRemoteSmtRequests OBJECT-TYPE
	SYNTAX	INTEGER {
				true(1),
				false(2)
			}
	ACCESS	read-write
	STATUS	deprecated
	DESCRIPTION
			"This object determines if this agent will proxy SMT
			requests to other FDDI stations.  If the value of this
			object is true(1), this agent will proxy SMT requests to
			other stations.  Note that only a subset of the above
			values may be valid for some systems."
::= { a3ComSysAgent 2 }

a3ComSysAgentRemoteSmtProxyRequestMaxAge OBJECT-TYPE
	SYNTAX	INTEGER (1..255)
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"The maximum time, in seconds, an SMT proxy request will
			remain queued waiting for a response before being
			discarded.  Note that when the value of
			a3ComSysAgentProxyRemoteSmtRequests is false(2), the value of
			this object is ignored."
::= { a3ComSysAgent 3 }

a3ComSysAgentProxyRemoteSmtEvents OBJECT-TYPE
	SYNTAX	INTEGER {
				true(1),
				false(2)
			}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"This object determines if this agent will generate traps
			for SMT events occuring at other stations.  If the value
			of this object is true(1), this agent will generate traps
			for all SMT events, those which occur locally, and those
			which occur at other stations.  If the value of this
			object is false(2), this agent will only generate traps
			for events which occur locally.  Note that only a subset
			of the above values may be valid for some systems."
::= { a3ComSysAgent 4 }

-- The Switching Systems MIB agent trap description table.

a3ComSysAgentTrapDescriptionTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysAgentTrapDescriptionTableEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"This table contains a listing of trap descriptions for
			each trap supported by this agent.  This 
			provides a relationship between a trap index, and the trap
			enterprise oid and trap number for a given trap.  In all
			cases except for the MIB-2 generic traps, the enterprise
			under which a trap is defined is the same as that
			appearing in the ENTERPRISE portion of the trap."
::= { a3ComSysAgent 5 }

a3ComSysAgentTrapDescriptionTableEntry OBJECT-TYPE
	SYNTAX	A3ComSysAgentTrapDescriptionTableEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"Information relating a trap index to a specific trap
			enterprise oid and trap number."
	INDEX	{ a3ComSysAgentTrapDescriptionIndex }
::= { a3ComSysAgentTrapDescriptionTable 1 }

A3ComSysAgentTrapDescriptionTableEntry ::=
	SEQUENCE {
		a3ComSysAgentTrapDescriptionIndex
			INTEGER,
		a3ComSysAgentTrapEnterprise
			OBJECT IDENTIFIER,
		a3ComSysAgentTrapNumber
			INTEGER
	}

a3ComSysAgentTrapDescriptionIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"A unique index corresponding to the trap described by
			this entry.  This value of this object corresponding to
			a particular trap will remain constant accross system
			resets."
::= { a3ComSysAgentTrapDescriptionTableEntry 1 }

a3ComSysAgentTrapEnterprise OBJECT-TYPE
	SYNTAX	OBJECT IDENTIFIER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The enterpise under which the trap identified by this
			entry is defined."
::= { a3ComSysAgentTrapDescriptionTableEntry 2 }

a3ComSysAgentTrapNumber OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of the trap identified by this entry, within
			the enterprise where it is defined."
::= { a3ComSysAgentTrapDescriptionTableEntry 3 }

-- The Switching Systems MIB agent trap destination table.

a3ComSysAgentTrapDestinationTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysAgentTrapDestinationTableEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"This table contains information specifying which traps
			will be transmitted to a given destination address.  The
			table is indexed by the destination address type and
			destination address.  Each entry in the table with a
			status of valid identifies a set of traps which, when
			generated, will be transmitted to the corresponding
			destination address listed in that entry."
::= { a3ComSysAgent 6 }

a3ComSysAgentTrapDestinationTableEntry OBJECT-TYPE
	SYNTAX	A3ComSysAgentTrapDestinationTableEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"Information relating a set of traps and a destination
			address to which each trap in ths set will be transmitted
			when it is generated.  To create a new entry, set a
			non-existent instance of a3ComSysAgentTrapDestinationTrapMask
			to a valid value.  To remove an entry, set the instance of
			a3ComSysAgentTrapDestinationEntryStatus for the entry to
			invalid(2)."
	INDEX	{ a3ComSysAgentTrapDestinationAddressType,
			a3ComSysAgentTrapDestinationAddress }
::= { a3ComSysAgentTrapDestinationTable 1 }

A3ComSysAgentTrapDestinationTableEntry ::=
	SEQUENCE {
		a3ComSysAgentTrapDestinationAddressType
			INTEGER,
		a3ComSysAgentTrapDestinationAddress
			OCTET STRING,
		a3ComSysAgentTrapDestinationTrapMask
			OCTET STRING,
		a3ComSysAgentTrapDestinationEntryStatus
			INTEGER
	}

a3ComSysAgentTrapDestinationAddressType OBJECT-TYPE
	SYNTAX	INTEGER {
				ip(1)
			}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The type of address identified by this entry."
::= { a3ComSysAgentTrapDestinationTableEntry 1 }

a3ComSysAgentTrapDestinationAddress OBJECT-TYPE
	SYNTAX	OCTET STRING
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The address, of the type specified by the corresponding
			value of a3ComSysAgentTrapDestinationAddressType, to which the
			set of traps identified by this entry are to be
			transmitted."
::= { a3ComSysAgentTrapDestinationTableEntry 2 }

a3ComSysAgentTrapDestinationTrapMask OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE (8))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"This value is a bit string that indicates which traps
			are enabled for the address identified by this entry.
			The octet string value is treated as a 64-bit value.  The
			value is a sum.  It initially takes on the value 0, then
			for each trap which is enabled, 2 raised to the value of
			(a3ComSysAgentTrapDescriptionIndex - 1) for that trap is
			added to the sum.  A new entry in the table is created by
			setting the value of this object for a new destination
			address type and destination address.  Note that an octet
			string of all zeros is not a valid value for this object."
::= { a3ComSysAgentTrapDestinationTableEntry 3 }

a3ComSysAgentTrapDestinationEntryStatus OBJECT-TYPE
	SYNTAX	INTEGER {
				valid(1),
				invalid(2)
			}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"The status of the trap destination table entry.  Setting
			this object to invalid(1) has the effect of removing the
			corresponding entry from the table."
::= { a3ComSysAgentTrapDestinationTableEntry 4 }

a3ComSysAgentReadCommunity OBJECT-TYPE
	SYNTAX  DisplayString (SIZE (0..48)) 
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
		"This object is the read community string when access is
		 made via SNMP, see RFC1157."	
::= { a3ComSysAgent 7 }

a3ComSysAgentReadWriteCommunity OBJECT-TYPE
	SYNTAX  DisplayString (SIZE (0..48)) 
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
		"This object is the read-write community string when access is
		made via SNMP, see RFC1157.  The read-write community string
	    is required to access this object."
::= { a3ComSysAgent 8 }


-- The Switching Systems MIB interface group.  Implementation of this
-- group is mandatory for all agents.

-- The Switching Systems MIB interface location table.

a3ComSysInterfaceLocationTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysInterfaceLocationEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A list of interface location entries.  A single entry
			exists in this list for each interface managed by this
			agent."
::= { a3ComSysInterface 1 }

a3ComSysInterfaceLocationEntry OBJECT-TYPE
	SYNTAX	A3ComSysInterfaceLocationEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"An interface location entry describes the location of
			a particular interface managed by this agent."
	INDEX	{ a3ComSysInterfaceLocationIfIndex }
::= { a3ComSysInterfaceLocationTable 1 }

A3ComSysInterfaceLocationEntry ::=
	SEQUENCE {
		a3ComSysInterfaceLocationIfIndex
			INTEGER,
		a3ComSysInterfaceLocationInterfaceType
			INTEGER,
		a3ComSysInterfaceLocationType
			INTEGER,
		a3ComSysInterfaceLocationTypeIndex
			INTEGER,
		a3ComSysInterfaceLocationLocalIndex
			INTEGER,
		a3ComSysInterfaceLocationSystemModuleIndex
			INTEGER
	}

a3ComSysInterfaceLocationIfIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The value of the MIB-II ifIndex corresponding to the
			interface identified by this entry."
::= { a3ComSysInterfaceLocationEntry 1 }


a3ComSysInterfaceLocationInterfaceType OBJECT-TYPE
	SYNTAX	INTEGER {
				other(1),
				ethernetPort(2),
				fddiMac(3),
				tokenringPort(4),
				atmPort(5)
			}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The type of the physical implementation of the interface
			identified by this entry."
::= { a3ComSysInterfaceLocationEntry 2 }

a3ComSysInterfaceLocationType OBJECT-TYPE
	SYNTAX	INTEGER {
				other(1),
				modularSlot(2),
				chassis(3),
				modularCard(4)
			}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The type of location where the interface identified
			by this entry is physically located."
::= { a3ComSysInterfaceLocationEntry 3 }

a3ComSysInterfaceLocationTypeIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the location identified by the corresponding
			instance of a3ComSysInterfaceLocationType where the interface
			identified by this entry is physically located."
::= { a3ComSysInterfaceLocationEntry 4 }

a3ComSysInterfaceLocationLocalIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The local index of the interface identified by
			this entry relative to its type specified by the
			corresponding value of a3ComSysInterfaceLocationInterfaceType,
			and the location specified by the corresponding values
			of a3ComSysInterfaceLocationType and a3ComSysInterfaceLocationTypeIndex."
::= { a3ComSysInterfaceLocationEntry 5 }

a3ComSysInterfaceLocationSystemModuleIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "The system module index of the interface idnetified by
         this entry.  Ths index can be used to acquire the module
         information from the s2SysModuleCardGroup and the
         a3ComSysDiagnosticsGroup groups."
::= { a3ComSysInterfaceLocationEntry 6 }
-- The Switching Systems MIB ethernet port group.  Implementation of
-- this group is mandatory for agents which manage ethernet port
-- resources.

a3ComSysEthernetPortCount OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The count of ethernet ports managed by this agent."
::= { a3ComSysEthernetPort 1 }

-- The Switching Systems MIB ethernet port table.

a3ComSysEthernetPortTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysEthernetPortEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A list of ethernet port entries.  A single entry exists
			in this list for each ethernet port managed by this agent."
::= { a3ComSysEthernetPort 2 }

a3ComSysEthernetPortEntry OBJECT-TYPE
	SYNTAX	A3ComSysEthernetPortEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"An ethernet port entry contains information about a
			particular ethernet port managed by this agent."
	INDEX	{ a3ComSysEthernetPortIndex }
::= { a3ComSysEthernetPortTable 1 }

A3ComSysEthernetPortEntry ::=
	SEQUENCE {
		a3ComSysEthernetPortIndex
			INTEGER,
		a3ComSysEthernetPortIfIndex
			INTEGER,
		a3ComSysEthernetPortLabel
			DisplayString,
		a3ComSysEthernetPortLinkStatus
			INTEGER,
		a3ComSysEthernetPortType
			INTEGER
}

a3ComSysEthernetPortIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the ethernet port identified by this entry,
			relative to this agent."
::= { a3ComSysEthernetPortEntry 1 }

a3ComSysEthernetPortIfIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The value of the MIB-II ifIndex corresponding to the
			ethernet port identified by this entry."
::= { a3ComSysEthernetPortEntry 2 }

a3ComSysEthernetPortLabel OBJECT-TYPE
	SYNTAX	DisplayString (SIZE (0..31))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"An ASCII text string describing the ethernet port
			identified by this entry."
::= { a3ComSysEthernetPortEntry 3 }

a3ComSysEthernetPortLinkStatus OBJECT-TYPE
	SYNTAX	INTEGER {
				active(1),
				inActive(2)
			}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The current value of the link status for the ethernet port
			identified by this entry."
::= { a3ComSysEthernetPortEntry 4 }

a3ComSysEthernetPortType OBJECT-TYPE
	SYNTAX	INTEGER {
				rj2110BaseT(1),
				rj4510BaseT(2),
				st10BaseFL(3),
				aui(4),
				bnc10Base2(5),
				other(6),
				rj45100BaseT(7),
				sc100BaseFx(8),
				untermBnc10Base2(9),
				sc1000BaseLxSm(10),
				sc1000BaseLxMm(11),
				sc1000BaseLxSmMm(12),
				sc1000BaseLx10km(13),
				sc1000BaseSx(14),
				hssdc1000BaseCx(15),
				db91000BaseCx(16),
				gbicNotPresent(17),
				gbic1000BaseCxDb9(18),
				gbic1000BaseCxHssdc(19),
				gbic1000BaseLx10Km(20),
				gbic1000BaseLx(21),
				gbic1000BaseSx(22),
				rj451000BaseT(23),
				port1000NotPresent(24)
			}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"Specific port type description for the ethernet port
			identified by this entry."
::= { a3ComSysEthernetPortEntry 5 }

-- The Switching Systems MIB ethernet port rate table.

a3ComSysEthernetPortRateTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysEthernetPortRateEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A list of ethernet port rate entries.  A single entry
			exists in this list for each ethernet port, managed by
			this agent, which supports rate information."
::= { a3ComSysEthernetPort 3 }

a3ComSysEthernetPortRateEntry OBJECT-TYPE
	SYNTAX	A3ComSysEthernetPortRateEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"An ethernet port rate entry contains rate statistics for a
			particular ethernet port managed by this agent.  Rate
			statistics are calculated based on a one second sampling
			interval."
	INDEX	{ a3ComSysEthernetPortRateIndex }
::= { a3ComSysEthernetPortRateTable 1 }

A3ComSysEthernetPortRateEntry ::=
	SEQUENCE {
		a3ComSysEthernetPortRateIndex
			INTEGER,
		a3ComSysEthernetPortRateByteReceiveRate
			INTEGER,
		a3ComSysEthernetPortRatePeakByteReceiveRate
			INTEGER,
		a3ComSysEthernetPortRateFrameReceiveRate
			INTEGER,
		a3ComSysEthernetPortRatePeakFrameReceiveRate
			INTEGER,
		a3ComSysEthernetPortRateByteTransmitRate
			INTEGER,
		a3ComSysEthernetPortRatePeakByteTransmitRate
			INTEGER,
		a3ComSysEthernetPortRateFrameTransmitRate
			INTEGER,
		a3ComSysEthernetPortRatePeakFrameTransmitRate
			INTEGER
}

a3ComSysEthernetPortRateIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the ethernet port identified by this entry,
			relative to this agent."
::= { a3ComSysEthernetPortRateEntry 1 }

a3ComSysEthernetPortRateByteReceiveRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The average number of bytes received per second by the
			ethernet port identified by this entry during the most
			recent sampling period."
::= { a3ComSysEthernetPortRateEntry 2 }

a3ComSysEthernetPortRatePeakByteReceiveRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The peak value of a3ComSysEthernetPortRateByteReceiveRate
			since the system was last initialized for the ethernet
			port identified by this entry."
::= { a3ComSysEthernetPortRateEntry 3 }

a3ComSysEthernetPortRateFrameReceiveRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The average number of frames received per second by the
			ethernet port identified by this entry during the most
			recent sampling period."
::= { a3ComSysEthernetPortRateEntry 4 }

a3ComSysEthernetPortRatePeakFrameReceiveRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The peak value of a3ComSysEthernetPortRateFrameReceiveRate
			since the system was last initialized for the ethernet
			port identified by this entry."
::= { a3ComSysEthernetPortRateEntry 5 }

a3ComSysEthernetPortRateByteTransmitRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The average number of bytes transmitted per second by the
			ethernet port identified by this entry during the most
			recent sampling period."
::= { a3ComSysEthernetPortRateEntry 6 }

a3ComSysEthernetPortRatePeakByteTransmitRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The peak value of a3ComSysEthernetPortRateByteTransmitRate
			since the system was last initialized for the ethernet
			port identified by this entry."
::= { a3ComSysEthernetPortRateEntry 7 }

a3ComSysEthernetPortRateFrameTransmitRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The average number of frames transmitted per second by the
			ethernet port identified by this entry during the most
			recent sampling period."
::= { a3ComSysEthernetPortRateEntry 8 }

a3ComSysEthernetPortRatePeakFrameTransmitRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The peak value of a3ComSysEthernetPortRateFrameTransmitRate
			since the system was last initialized for the ethernet
			port identified by this entry."
::= { a3ComSysEthernetPortRateEntry 9 }


-- The Switching Systems MIB SMT group.  Implementation of this group is
-- mandatory for agents which manage SMT resources.

a3ComSysSmtCount OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The count of SMTs managed by this agent."
::= { a3ComSysSmt 1 }

-- The Switching Systems MIB SMT table.
-- This table is currently unused and is reserved for future use.
-- { a3ComSysSmt 2 }

-- The Switching Systems MIB SMT FDDI MAC table.
-- This table is currently unused and is reserved for future use.
-- { a3ComSysSmt 3 }

-- The Switching Systems MIB SMT FDDI MAC beacon table.

a3ComSysSmtFddiMacBeaconTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysSmtFddiMacBeaconEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A list of FDDI MAC beacon entries.  A single entry exists
			in this list for each FDDI MAC, managed by this agent,
			which supports MAC beacon history."
::= { a3ComSysSmt 4 }

a3ComSysSmtFddiMacBeaconEntry OBJECT-TYPE
	SYNTAX	A3ComSysSmtFddiMacBeaconEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"An FDDI MAC beacon entry contains information about a
			particular FDDI MAC's beacon history."
	INDEX	{ a3ComSysSmtFddiMacBeaconSmtIndex,
			a3ComSysSmtFddiMacBeaconIndex }
::= { a3ComSysSmtFddiMacBeaconTable 1 }

A3ComSysSmtFddiMacBeaconEntry ::=
	SEQUENCE {
		a3ComSysSmtFddiMacBeaconSmtIndex
			INTEGER,
		a3ComSysSmtFddiMacBeaconIndex
			INTEGER,
		a3ComSysSmtFddiMacBeaconHistory
			OCTET STRING
}

a3ComSysSmtFddiMacBeaconSmtIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the SMT instance identified by this entry,
			relative to this agent."
	::= { a3ComSysSmtFddiMacBeaconEntry 1 }

a3ComSysSmtFddiMacBeaconIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the FDDI MAC identified by this entry,
			within the SMT identified by this entry."
::= { a3ComSysSmtFddiMacBeaconEntry 2 }

a3ComSysSmtFddiMacBeaconHistory OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE (0..256))
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"This object gives a history of the most recent beacon
			information received on the FDDI MAC identified by this
			entry.  It can contain up to a maximum of eight records.
			Each record is of the form:
				source MAC:				6 bytes
				beacon data length:		2 bytes.
				beacon data:			0-16 bytes."
::= { a3ComSysSmtFddiMacBeaconEntry 3 }

-- The Switching Systems MIB SMT FDDI MAC rate table.

a3ComSysSmtFddiMacRateTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysSmtFddiMacRateEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A list of FDDI MAC rate entries.  A single entry exists
			in this list for each FDDI MAC, managed by this agent,
			which supports rate statistics."
::= { a3ComSysSmt 5 }

a3ComSysSmtFddiMacRateEntry OBJECT-TYPE
	SYNTAX	A3ComSysSmtFddiMacRateEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"An FDDI MAC rate entry contains rate statistics for a
			particular FDDI MAC managed by this agent.  Rate statistics
			are calculated based on a one second sampling interval."
	INDEX	{ a3ComSysSmtFddiMacRateSmtIndex,
			a3ComSysSmtFddiMacRateIndex }
::= { a3ComSysSmtFddiMacRateTable 1 }

A3ComSysSmtFddiMacRateEntry ::=
	SEQUENCE {
		a3ComSysSmtFddiMacRateSmtIndex
			INTEGER,
		a3ComSysSmtFddiMacRateIndex
			INTEGER,
		a3ComSysSmtFddiMacRateByteReceiveRate
			INTEGER,
		a3ComSysSmtFddiMacRatePeakByteReceiveRate
			INTEGER,
		a3ComSysSmtFddiMacRateFrameReceiveRate
			INTEGER,
		a3ComSysSmtFddiMacRatePeakFrameReceiveRate
			INTEGER,
		a3ComSysSmtFddiMacRateByteTransmitRate
			INTEGER,
		a3ComSysSmtFddiMacRatePeakByteTransmitRate
			INTEGER,
		a3ComSysSmtFddiMacRateFrameTransmitRate
			INTEGER,
		a3ComSysSmtFddiMacRatePeakFrameTransmitRate
			INTEGER
	}

a3ComSysSmtFddiMacRateSmtIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the SMT instance identified by this entry,
			relative to this agent."
::= { a3ComSysSmtFddiMacRateEntry 1 }

a3ComSysSmtFddiMacRateIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the FDDI MAC identified by this entry, within
			the SMT identified by this entry."
::= { a3ComSysSmtFddiMacRateEntry 2 }

a3ComSysSmtFddiMacRateByteReceiveRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The average number of bytes received per second by the
			FDDI MAC identified by this entry during the most recent
			sampling period."
::= { a3ComSysSmtFddiMacRateEntry 3 }

a3ComSysSmtFddiMacRatePeakByteReceiveRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The peak value of a3ComSysSmtFddiMacByteReceiveRate since the
			system was last initialized for the FDDI MAC identified by
			this entry."
::= { a3ComSysSmtFddiMacRateEntry 4 }

a3ComSysSmtFddiMacRateFrameReceiveRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The average number of frames received per second by the
			FDDI MAC identified by this entry during the most recent
			sampling period."
::= { a3ComSysSmtFddiMacRateEntry 5 }

a3ComSysSmtFddiMacRatePeakFrameReceiveRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The peak value of a3ComSysSmtFddiMacRateFrameReceiveRate since
			the system was last initialized for the FDDI MAC identified
			by this entry."
::= { a3ComSysSmtFddiMacRateEntry 6 }

a3ComSysSmtFddiMacRateByteTransmitRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The average number of bytes transmitted per second by the
			FDDI MAC identified by this entry during the most recent
			sampling period."
::= { a3ComSysSmtFddiMacRateEntry 7 }

a3ComSysSmtFddiMacRatePeakByteTransmitRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The peak value of a3ComSysSmtFddiMacByteTransmitRate since the
			system was last initialized for the FDDI MAC identified by
			this entry."
::= { a3ComSysSmtFddiMacRateEntry 8 }

a3ComSysSmtFddiMacRateFrameTransmitRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The average number of frames transmitted per second by
			the FDDI MAC identified by this entry during the most
			recent sampling period."
	::= { a3ComSysSmtFddiMacRateEntry 9 }

a3ComSysSmtFddiMacRatePeakFrameTransmitRate OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The peak value of a3ComSysSmtFddiMacFrameTransmitRate since the
			system was last initialized for the FDDI MAC identified by
			this entry."
::= { a3ComSysSmtFddiMacRateEntry 10 }

-- The Switching Systems MIB SMT FDDI port table.

a3ComSysSmtFddiPortTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysSmtFddiPortEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A list of FDDI port entries.  A single entry exists in
			this list for each FDDI port managed by this agent."
::= { a3ComSysSmt 6 }

a3ComSysSmtFddiPortEntry OBJECT-TYPE
	SYNTAX	A3ComSysSmtFddiPortEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"An FDDI port entry contains information about a particular
			FDDI port managed by this agent."
	INDEX	{ a3ComSysSmtFddiPortSmtIndex,
			a3ComSysSmtFddiPortIndex }
::= { a3ComSysSmtFddiPortTable 1 }

A3ComSysSmtFddiPortEntry ::=
	SEQUENCE {
		a3ComSysSmtFddiPortSmtIndex
			INTEGER,
		a3ComSysSmtFddiPortIndex
			INTEGER,
		a3ComSysSmtFddiPortLocationType
			INTEGER,
		a3ComSysSmtFddiPortLocationTypeIndex
			INTEGER,
		a3ComSysSmtFddiPortLocationLocalIndex
			INTEGER,
		a3ComSysSmtFddiPortLabel
			DisplayString
	}

a3ComSysSmtFddiPortSmtIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the SMT instance identified by this entry,
			relative to this agent."
::= { a3ComSysSmtFddiPortEntry 1 }

a3ComSysSmtFddiPortIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the FDDI port identified by this entry,
			within the SMT identified by this entry."
::= { a3ComSysSmtFddiPortEntry 2 }

a3ComSysSmtFddiPortLocationType OBJECT-TYPE
	SYNTAX	INTEGER {
				other(1),
				modularSlot(2),
				chassis(3),
				modularCard(4)
			}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The type of location where the FDDI port identified by
			this entry is physically located."
::= { a3ComSysSmtFddiPortEntry 3 }

a3ComSysSmtFddiPortLocationTypeIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the location identified by the corresponding
			instance of a3ComSysSmtFddiPortLocationType where the FDDI port
			identified by this entry is physically located."
::= { a3ComSysSmtFddiPortEntry 4 }

a3ComSysSmtFddiPortLocationLocalIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The local index of the FDDI port identified by this
			entry relative to the location specified by the
			corresponding values of a3ComSysSmtFddiPortLocationType and
			a3ComSysSmtFddiPortLocationTypeIndex."
::= { a3ComSysSmtFddiPortEntry 5 }

a3ComSysSmtFddiPortLabel OBJECT-TYPE
	SYNTAX	DisplayString (SIZE (0..31))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"An ASCII text string describing the FDDI port identified
			by this entry."
::= { a3ComSysSmtFddiPortEntry 6 }

a3ComSysSmtFddiMacLocationTable OBJECT-TYPE
	SYNTAX SEQUENCE OF A3ComSysSmtFddiMacLocationEntry
	ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
		"An FDDI MAC Location table contains information to assign
		an FDDI MAC to a different Location.  The system must be
		rebooted after all changes to this table are completed
		in order that the changes take effect."
::= { a3ComSysSmt 7 }

a3ComSysSmtFddiMacLocationEntry OBJECT-TYPE
	SYNTAX A3ComSysSmtFddiMacLocationEntry
	ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
		"An FDDI MAC entry contains information to assign
		an FDDI MAC to a different Location."
	INDEX { a3ComSysSmtFddiMacLocationSmtIndex,
			a3ComSysSmtFddiMacLocationIndex }
::= { a3ComSysSmtFddiMacLocationTable 1 }

A3ComSysSmtFddiMacLocationEntry ::=
	SEQUENCE {
		a3ComSysSmtFddiMacLocationSmtIndex INTEGER,
		a3ComSysSmtFddiMacLocationIndex INTEGER,
		a3ComSysSmtFddiMacCurrentLocation INTEGER,
		a3ComSysSmtFddiMacRequestedLocation INTEGER,
		a3ComSysSmtFddiMacAvailableLocation INTEGER
	}

a3ComSysSmtFddiMacLocationSmtIndex OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The index of the SMT instance identified by this entry,
		relative to the agent."
::= { a3ComSysSmtFddiMacLocationEntry 1 }

a3ComSysSmtFddiMacLocationIndex OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The index of the FDDI MAC instance identified by this entry,
		relative to the SMT identified by this entry."
::= { a3ComSysSmtFddiMacLocationEntry 2 }

a3ComSysSmtFddiMacCurrentLocation OBJECT-TYPE
	SYNTAX INTEGER {
		internalBackplane(1),
		externalFddiPort(2)
	}
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicates whether the MAC identified by this entry is assigned
		to a backplane FDDI station (internal) or an FDDI station
		configured on a module (external.)"
::= { a3ComSysSmtFddiMacLocationEntry 3 }

a3ComSysSmtFddiMacRequestedLocation OBJECT-TYPE
	SYNTAX INTEGER {
		internalBackplane(1),
		externalFddiPort(2)
	}
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The Location which the MAC identified by this entry is to
		be assigned to during the next reboot."
::= { a3ComSysSmtFddiMacLocationEntry 4 }

a3ComSysSmtFddiMacAvailableLocation OBJECT-TYPE
	SYNTAX INTEGER{
		internalBackplane(1),
		externalFddiPort(2),
		internalOrExternal(3)
	}
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicates the Location(s) available for this MAC.  A mac Location
		 which can be modified to either the interanl backplane or an
		 external FDDI port is indicated by internalOrExternal(3)."
::= { a3ComSysSmtFddiMacLocationEntry 5 }

a3ComSysSmtFddiMacStationTable OBJECT-TYPE
	SYNTAX SEQUENCE OF A3ComSysSmtFddiMacStationEntry
	ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
		"An FDDI station MAC table contains information to assign
		an FDDI MAC to an FDDI Station.  The system must be
		rebooted after all changes to this table are completed 
		in order that the changes take effect."
::= { a3ComSysSmt 8 }

a3ComSysSmtFddiMacStationEntry OBJECT-TYPE
	SYNTAX A3ComSysSmtFddiMacStationEntry
	ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
		"An FDDI MAC entry contains information to assign
		an FDDI MAC to an FDDI Station."
	INDEX { a3ComSysSmtFddiMacStationSmtIndex,
			a3ComSysSmtFddiMacStationIndex }
::= { a3ComSysSmtFddiMacStationTable 1 }

A3ComSysSmtFddiMacStationEntry ::=
	SEQUENCE {
		a3ComSysSmtFddiMacStationSmtIndex INTEGER,
		a3ComSysSmtFddiMacStationIndex INTEGER,
		a3ComSysSmtFddiMacCurrentStation INTEGER,
		a3ComSysSmtFddiMacRequestedStation INTEGER,
		a3ComSysSmtFddiMacAvailableStations INTEGER
	}

a3ComSysSmtFddiMacStationSmtIndex OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The index of the SMT instance identified by this entry,
		relative to this agent."
::= { a3ComSysSmtFddiMacStationEntry 1 }

a3ComSysSmtFddiMacStationIndex OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The index of the MAC instance identified by this entry,
		relative to the SMT identified by this entry."
::= { a3ComSysSmtFddiMacStationEntry 2 }

a3ComSysSmtFddiMacCurrentStation OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicates which FDDI station that the FDDI MAC identified
		by this entry is assigned to. A value of 0 indicates
		that the mac is assigned to an external station. Otherwise
		the value represents the internal backplane station number."
::= { a3ComSysSmtFddiMacStationEntry 3 }

a3ComSysSmtFddiMacRequestedStation OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicates which FDDI station the FDDI MAC identified
		by this entry will be set to during the next system reboot.
		A value of 0 indicates an external station. Otherwise the
		value represents the internal backplane	station number."
::= { a3ComSysSmtFddiMacStationEntry 4 }

a3ComSysSmtFddiMacAvailableStations OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"This value is a sum. Setting of the first bit (LSB)
		indicates that the MAC can be assigned to an external
		station. Available backplane stations are indicated
		by adding 2^StationNumber to the sum.  Where StationNumber
		represents a backplane station number."
::= { a3ComSysSmtFddiMacStationEntry 5 }

a3ComSysSmtFddiPortStationTable OBJECT-TYPE
	SYNTAX SEQUENCE OF A3ComSysSmtFddiPortStationEntry
	ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
		"An FDDI station Port table contains information to assign
		an FDDI Port to an FDDI Station.  The system must be
		rebooted after all changes to this table are completed 
		in order that the changes take effect."
::= { a3ComSysSmt 9 }

a3ComSysSmtFddiPortStationEntry OBJECT-TYPE
	SYNTAX A3ComSysSmtFddiPortStationEntry
	ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
		"An FDDI Port entry contains information to assign
		an FDDI Port to an FDDI Station."
	INDEX { a3ComSysSmtFddiPortStationSmtIndex,
			a3ComSysSmtFddiPortStationIndex }
::= { a3ComSysSmtFddiPortStationTable 1 }

A3ComSysSmtFddiPortStationEntry ::=
	SEQUENCE {
		a3ComSysSmtFddiPortStationSmtIndex INTEGER,
		a3ComSysSmtFddiPortStationIndex INTEGER,
		a3ComSysSmtFddiPortCurrentStation INTEGER,
		a3ComSysSmtFddiPortRequestedStation INTEGER,
		a3ComSysSmtFddiPortAvailableStations INTEGER
	}

a3ComSysSmtFddiPortStationSmtIndex OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	"The index of the SMT instance identified by this entry,
	relative to this agent."
::= { a3ComSysSmtFddiPortStationEntry 1 }

a3ComSysSmtFddiPortStationIndex OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The index of the Port instance identified by this entry,
		relative to the SMT indentified by this entry."
::= { a3ComSysSmtFddiPortStationEntry 2 }

a3ComSysSmtFddiPortCurrentStation OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicates which FDDI station the FDDI Port identified
		by this entry is assigned to. A value of 0 indicates
		that the Port is assigned to an external station. Otherwise
		the value represents the internal backplane station number."
::= { a3ComSysSmtFddiPortStationEntry 3 }

a3ComSysSmtFddiPortRequestedStation OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicates which FDDI station the FDDI port identified
		by this entry will be set to during the next system reboot.
		A value of 0 indicates an external station. Otherwise the
		value represents the internal backplane	station number."
::= { a3ComSysSmtFddiPortStationEntry 4 }

a3ComSysSmtFddiPortAvailableStations OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"This value is a sum. Setting of the first bit
		indicates that the port can be assigned to an external
		station. Available backplane stations are indicated
		by adding 2^StationNumber to the sum.  Where StationNumber
		represents a backplane station number."
::= { a3ComSysSmtFddiPortStationEntry 5 }



-- The Switching Systems MIB bridge group.  Implementation of this group
-- is mandatory for agents which manage bridge resources.

a3ComSysBridgeCount OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The count of bridges managed by this agent."
::= { a3ComSysBridge 1 }

-- The Switching Systems MIB bridge table.

a3ComSysBridgeTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysBridgeEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A list of bridge entries.  A single entry exists in this
			list for each bridge managed by this agent."
::= { a3ComSysBridge 2 }

a3ComSysBridgeEntry OBJECT-TYPE
	SYNTAX	A3ComSysBridgeEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A bridge entry contains information about a particular
			bridge managed by this agent."
	INDEX	{ a3ComSysBridgeIndex }
::= { a3ComSysBridgeTable 1 }
						
A3ComSysBridgeEntry ::=
	SEQUENCE {
		a3ComSysBridgeIndex
			INTEGER,
		a3ComSysBridgePortCount
			INTEGER,
		a3ComSysBridgeAddressTableSize
			INTEGER,
		a3ComSysBridgeAddressTableCount
			INTEGER,
		a3ComSysBridgeAddressTablePeakCount
			INTEGER,
		a3ComSysBridgeAddressThreshold
			INTEGER,
		a3ComSysBridgeMode
			INTEGER,
		a3ComSysBridgeBackbonePort
			INTEGER,
		a3ComSysBridgeIpFragmentationEnabled
			INTEGER,
		a3ComSysBridgeTrFddiTranslationMode
			INTEGER,
		a3ComSysBridgeSTPGroupAddress 
			OCTET STRING,
		a3ComSysBridgeSTPEnable
			INTEGER,
		a3ComSysBridgeIpxSnapTranslationEnable
			INTEGER,
		a3ComSysBridgeLowLatencyEnable
			INTEGER,
		a3ComSysBridgeVlanMode
			INTEGER
		}


a3ComSysBridgeIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the bridge identified by this entry,
			relative to this agent."
::= { a3ComSysBridgeEntry 1 }

a3ComSysBridgePortCount OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of bridge ports that the bridge identified by
			this entry controls."
::= { a3ComSysBridgeEntry 2 }

a3ComSysBridgeAddressTableSize OBJECT-TYPE
	SYNTAX	INTEGER 
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The size of the address table for the bridge identified
			by this entry."
::= { a3ComSysBridgeEntry 3 }

a3ComSysBridgeAddressTableCount OBJECT-TYPE
	SYNTAX	INTEGER 
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The current count of addresses in the address table for
			the bridge identified by this entry."
::= { a3ComSysBridgeEntry 4 }

a3ComSysBridgeAddressTablePeakCount OBJECT-TYPE
	SYNTAX	INTEGER 
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The peak count of addresses in the address table for the
			bridge identified by this entry, since the system was last
			initialized."
::= { a3ComSysBridgeEntry 5 }

a3ComSysBridgeAddressThreshold OBJECT-TYPE
	SYNTAX	INTEGER 
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"A reporting threshold for the total number of addresses
			known for the bridge identified by this entry.  When this
			threshold is reached, the event
			a3ComSysBridgeAddressThresholdEvent is generated.  The range of
			valid values for setting this object is between 1 and the
			corresponding value reported by a3ComSysBridgeAddressTableSize
			+ 1 (Note that this range applies to values issued in set
			requests.  The current value may be outside this range,
			for example if the corresponding value of a3ComSysBridgeMode is
			changed). Setting this object to one greater than the
			address table size disables the generation of
			a3ComSysBridgeAddressThresholdEvents since the limit will never
			be reached."
::= { a3ComSysBridgeEntry 6 }

a3ComSysBridgeMode OBJECT-TYPE
	SYNTAX	INTEGER {
			expressMode(1),
			ieee8021dBridgeMode(2),
			notSupported(3),
			ieee8021dSRTBridgeMode(4),
			ieee8021dSRBridgeMode(5),
			ibmSRBridgeMode(6),
			srtBBridgeMode(7),
			srExpressBridgeMode(8)
			}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"The operational mode of the bridge identified by this
			entry.  Note that bridges which report notSupported(3)
			will not support sets of this object, and that the value
			notSupported(3) is not a valid value for a set operation."
::= { a3ComSysBridgeEntry 7 }

a3ComSysBridgeBackbonePort OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"The number of the port selected as the backbone segment
			port when the corresponding value of a3ComSysBridgeMode is
			is expressMode(1).  The value of this object can range
			from 1 to the corresponding value of a3ComSysBridgePortCount,
			however, some bridges may support only a subset of ports
			as backbone ports.  If the corresponding value of
			a3ComSysBridgeMode is not expressMode(1), the value of this
			object is ignored."
::= { a3ComSysBridgeEntry 8 }

a3ComSysBridgeIpFragmentationEnabled OBJECT-TYPE
	SYNTAX	INTEGER {
				true(1),
				false(2),
				notSupported(3)
			}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"A flag indicating whether or not IP fragmentation is
			enabled on this bridge.  Note that bridges which report
			notSupported(3) will not support sets of this object, and
			that the value notSupported(3) is not a valid value for a
			set operation."
::= { a3ComSysBridgeEntry 9 }

a3ComSysBridgeTrFddiTranslationMode OBJECT-TYPE
	SYNTAX	INTEGER {
			native(1),
			backbone(2)
			}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"The mode used to describe whether the embedded MAC
			addresses are byte-conjugated in order to convert them
			from Token Ring format to native FDDI format (and vice
			versa), or whether they are left alone (used for traffic
			flowing	across a FDDI backbone to/from Token Ring end
			stations)."
::= { a3ComSysBridgeEntry 10 }

a3ComSysBridgeSTPGroupAddress OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE (6)) -- 6 octet address in "canonical" order
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
			"Spanning tree bridge group address. The address cannot be 
			changed if the spanning tree is enabled (a3ComSysBridgeStpEnabled)."
::= { a3ComSysBridgeEntry 11 }

a3ComSysBridgeSTPEnable OBJECT-TYPE
	SYNTAX  INTEGER {
				true(1),
				false(2)
			}
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
	"This object indicates if spanning tree bridge feature is
	enabled or disabled.  If enabled this value will equal true(1)."
::= { a3ComSysBridgeEntry 12 }

a3ComSysBridgeIpxSnapTranslationEnable OBJECT-TYPE
	SYNTAX  INTEGER {
				true(1),
				false(2)
			}
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
		"This object indicates if the IPX 802.3-FDDI SNAP Translation
		 bridge feature is enabled or disabled.  If enabled this
		 value will equal true(1). Note, this object may not be
		 supported on all bridges."
::= { a3ComSysBridgeEntry 13  }

a3ComSysBridgeLowLatencyEnable OBJECT-TYPE
	SYNTAX  INTEGER {
				true(1),
				false(2)
			}
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
		"This object indicates if the bridge low latency
		 feature is enabled or disabled.  If enabled this
		 value will equal true(1). Note, this object may not be
		 supported on all bridges."
::= { a3ComSysBridgeEntry 14  }

a3ComSysBridgeVlanMode OBJECT-TYPE
	SYNTAX  INTEGER {
		open(1),
		closed(2),
		mixed(3),
		notSupported(4)
		}
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
		"This object indicates the VLAN types that this
		bridge will support.  Open mode means that each VLAN
		within this bridge will be of the Open type; all VLANs
		within this bridge will share the same address table.
		Closed mode means that each VLAN within this bridge
		will be of the Closed type; each VLAN within this
		bridge will have its own address table.  Mixed mode
		means that each VLAN within this bridge with be of
		either the Open or Closed type; all Open VLANs will
		share the same address table and each Closed VLAN
		will have its own address table."
::= { a3ComSysBridgeEntry 15  }

-- The Switching Systems MIB bridge port table.

a3ComSysBridgePortTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysBridgePortEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A list of bridge port entries.  A single entry exists in
			this list for each bridge port managed by this agent."
::= { a3ComSysBridge 3 }

a3ComSysBridgePortEntry OBJECT-TYPE
	SYNTAX	A3ComSysBridgePortEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A bridge port entry contains information about a
			particular bridge port managed by this agent."
	INDEX	{ a3ComSysBridgePortBridgeIndex,
					a3ComSysBridgePortIndex }
::= { a3ComSysBridgePortTable 1 }

A3ComSysBridgePortEntry ::=
	SEQUENCE {
		a3ComSysBridgePortBridgeIndex
			INTEGER,
		a3ComSysBridgePortIndex
			INTEGER,
		a3ComSysBridgePortIfIndex
			INTEGER,
		a3ComSysBridgePortReceiveMulticastLimit
			INTEGER,
		a3ComSysBridgePortAddressAction
			INTEGER,
		a3ComSysBridgePortSpanningTreeFrameReceivedCounts
			Counter,
		a3ComSysBridgePortReceiveBlockedDiscards
			Counter,
		a3ComSysBridgePortReceiveMulticastLimitExceededs
			Counter,
		a3ComSysBridgePortReceiveMulticastLimitExceededDiscards
			Counter,
		a3ComSysBridgePortReceiveSecurityDiscards
			Counter,
		a3ComSysBridgePortReceiveUnknownDiscards
			Counter,
		a3ComSysBridgePortReceiveOtherDiscards
			Counter,
		a3ComSysBridgePortReceiveErrorDiscards
			Counter,
		a3ComSysBridgePortSameSegmentDiscards
			Counter,
		a3ComSysBridgePortTransmitBlockedDiscards
			Counter,
		a3ComSysBridgePortReceiveAllPathFilteredFrames
			Counter,
		a3ComSysBridgePortReceiveMulticastPathFilteredFrames
			Counter,
		a3ComSysBridgePortTransmitAllPathFilteredFrames
			Counter,
		a3ComSysBridgePortTransmitMulticastPathFilteredFrames
			Counter,
		a3ComSysBridgePortForwardedUnicastFrames
			Counter,
		a3ComSysBridgePortForwardedUnicastOctets
			Counter,
		a3ComSysBridgePortForwardedMulticastFrames
			Counter,
		a3ComSysBridgePortForwardedMulticastOctets
			Counter,
		a3ComSysBridgePortFloodedUnicastFrames
			Counter,
		a3ComSysBridgePortFloodedUnicastOctets
			Counter,
		a3ComSysBridgePortStpMode
			INTEGER,
		a3ComSysBridgePortReceiveMulticastLimitFrameType
			INTEGER,
		a3ComSysBridgePortForwardedFrames
			Counter,
		a3ComSysBridgePortReceiveMulticastLimitMultiplier
			INTEGER
	}

a3ComSysBridgePortBridgeIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the bridge identified by this entry,
			relative to this agent."
::= { a3ComSysBridgePortEntry 1 }

a3ComSysBridgePortIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the bridge port identified by this entry,
			within the bridge identified by this entry."
::= { a3ComSysBridgePortEntry 2 }

a3ComSysBridgePortIfIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The value of the MIB-II ifIndex corresponding to the
			bridge port identified by this entry."
::= { a3ComSysBridgePortEntry 3 }

a3ComSysBridgePortReceiveMulticastLimit OBJECT-TYPE
	SYNTAX	INTEGER (0..65535)
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"This variable limits the number of multicast frames forwarded
			by this port over a 1 second interval.  The minimum threshold
			limit may vary between platforms, but can be determined by multiplying
			this value by the a3ComSysBridgePortReceiveMulticastLimitMultiplier
			value.  For example if this value equals 2, and the 
			a3ComSysBridgePortReceiveMulticastLimitMultiplier equals 1000 then no 
			more than 2000 multicast frames per second will be forwarded by this port.

			The default value for this object is zero which an infinite rate."
::= { a3ComSysBridgePortEntry 4 }

a3ComSysBridgePortAddressAction OBJECT-TYPE
	SYNTAX	INTEGER {
				other(1),
				freezeAddress(2),
				flushAddress(3),
				flushDynamicAddress(4)
					}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"This object, when read, always returns the value
			other(1).  The behavior of setting this object to each of
			the acceptable values is as follows:

				freezeAddress:	causes all the learned dynamic
								addresses to be converted into static
								addresses.

				flushAddress:   causes all the addresses to be flushed
								from the address list for the bridge
								port identified by this entry.

				flushDynamicAddress:
								causes all dynamic addresses to be
								flushed from the address list for the
								bridge port identified by this entry."
::= { a3ComSysBridgePortEntry 5 }

a3ComSysBridgePortSpanningTreeFrameReceivedCounts OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of spanning tree frames received by the
			bridge port identified by this entry."
::= { a3ComSysBridgePortEntry 6 }

a3ComSysBridgePortReceiveBlockedDiscards OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of frames discarded by the bridge port
			identified by this entry because the receiving bridge port
			was not in the 'forwarding' state."
::= { a3ComSysBridgePortEntry 7 }

a3ComSysBridgePortReceiveMulticastLimitExceededs OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of times the value of
			a3ComSysBridgePortReceiveMulticastLimit was exceeded for the
			port identified by this entry."
::= { a3ComSysBridgePortEntry 8 }

a3ComSysBridgePortReceiveMulticastLimitExceededDiscards OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of multicast/broadcast frames discarded by the
			bridge port identified by this entry because the
			corresponding value of a3ComSysBridgePortReceiveMulticastLimit
			was exceeded."
::= { a3ComSysBridgePortEntry 9 }

a3ComSysBridgePortReceiveSecurityDiscards OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of frames discarded by the bridge port
			identified by this entry because they contained source
			addresses which were statically configured on another
			bridge port.  A statically configured address (station),
			which is not allowed to move, appears to have moved."
::= { a3ComSysBridgePortEntry 10 }

a3ComSysBridgePortReceiveUnknownDiscards OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of frames discarded by the bridge port
			identified by this entry because the destination address
			was unknown.  Note that this counter is only valid for
			backbone ports, and only when the bridge is operating in
			express mode."
::= { a3ComSysBridgePortEntry 11 }

a3ComSysBridgePortReceiveOtherDiscards OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of frames discarded by the bridge port
			identified by this entry because they contained either
			invalid (group) source addresses or source addresses
			belonging to this bridge (indicative of network loops)."
::= { a3ComSysBridgePortEntry 12 }

a3ComSysBridgePortReceiveErrorDiscards OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of frames discarded by the bridge port
			identified by this entry because of internal bridge system
			errors (e.g., hardware and software address table
			discrepencies)."
::= { a3ComSysBridgePortEntry 13 }

a3ComSysBridgePortSameSegmentDiscards OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of frames discarded by the bridge port
			identified by this entry because the destination address
			is known on the same network segment as the source address,
			i.e., the frame does not need to be bridged."
::= { a3ComSysBridgePortEntry 14 }

a3ComSysBridgePortTransmitBlockedDiscards OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of frames discarded by the bridge port
			identified by this entry because the transmitting bridge
			port was not in the 'forwarding' state."
::= { a3ComSysBridgePortEntry 15 }

a3ComSysBridgePortReceiveAllPathFilteredFrames OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of frames discarded by the bridge port
			identified by this entry due to user defined receive all
			path filters."
::= { a3ComSysBridgePortEntry 16 }

a3ComSysBridgePortReceiveMulticastPathFilteredFrames OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of frames discarded by the bridge port
			identified by this entry due to user defined receive
			multicast path filters."
::= { a3ComSysBridgePortEntry 17 }

a3ComSysBridgePortTransmitAllPathFilteredFrames OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of frames discarded by the bridge port
			identified by this entry due to user defined transmit all
			path filters."
::= { a3ComSysBridgePortEntry 18 }

a3ComSysBridgePortTransmitMulticastPathFilteredFrames OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of frames discarded by the bridge port
			identified by this entry due to user defined transmit
			multicast path filters."
::= { a3ComSysBridgePortEntry 19 }

a3ComSysBridgePortForwardedUnicastFrames OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of unicast frames which this port forwarded
			to a single destination port."
::= { a3ComSysBridgePortEntry 20 }

a3ComSysBridgePortForwardedUnicastOctets OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of octets contained in unicast frames
			which this port forwarded to a single destination port."
::= { a3ComSysBridgePortEntry 21 }

a3ComSysBridgePortForwardedMulticastFrames OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of multicast frames which this port forwarded."
::= { a3ComSysBridgePortEntry 22 }

a3ComSysBridgePortForwardedMulticastOctets OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of octets contained in multicast frames which
			this port forwarded."
::= { a3ComSysBridgePortEntry 23 }

a3ComSysBridgePortFloodedUnicastFrames OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of unicast frames which this port flooded to
			all other ports in the bridge."
::= { a3ComSysBridgePortEntry 24 }

a3ComSysBridgePortFloodedUnicastOctets OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The number of octets contained in unicast frames which
			this port flooded to all other ports in the bridge."
::= { a3ComSysBridgePortEntry 25 }


a3ComSysBridgePortStpMode OBJECT-TYPE
	SYNTAX  INTEGER {
				enable(1),
				disable(2),
				remove(3)
				}
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
			"The mode of the bridge port."
	REFERENCE
			"IEEE 802.1D-1990: Section 4.5.5.2 for enable and disable modes."
::= { a3ComSysBridgePortEntry 26 }

a3ComSysBridgePortReceiveMulticastLimitFrameType OBJECT-TYPE
	SYNTAX  INTEGER {
				broadcastAndMulticast(1),
				broadcastOnly(2)
			}
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
		"This object identifies the frames type(s) that are to be
		counted when determining if the receive multicast limit
		has been exceeded for this bridge port.  Devices attached
		to networks with predominantly high multicast traffic
		(e.g. video) should set this value to broadcastOnly(2)
		to detect broadcast storms."
::= { a3ComSysBridgePortEntry 27 }

a3ComSysBridgePortForwardedFrames OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The number of frames which this port forwarded."
::= { a3ComSysBridgePortEntry 28 }


a3ComSysBridgePortReceiveMulticastLimitMultiplier OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This variable determines the minimum setting for the multicast
		limit threshold.  For example if this value equals 1000, and the
		a3ComSysBridgePortReceiveMulticastLimit variable equals 2 then
		no more than 2000 multicast frames per second will be forwarded 
		by this port."
::= { a3ComSysBridgePortEntry 29 }



--	::= { a3ComSysBridge 4 } Reserved.  Do not use.


-- The Switching Systems MIB bridge port address table

a3ComSysBridgePortAddressTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysBridgePortAddressEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A list of bridge port address information.  A single
			entry exists in this list for each learned address,
			accross all bridge ports and all bridges managed by this
			agent."
::= { a3ComSysBridge 5 }

a3ComSysBridgePortAddressEntry OBJECT-TYPE
	SYNTAX	A3ComSysBridgePortAddressEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"An bridge port address entry contains information about a
			particular bridge port address.  To create a new entry,
			set an instance of a3ComSysBridgePortAddressRemoteAddress with
			the address index portion of the instance set to 0, to a
			valid value.  To remove an entry, set the instance of the
			a3ComSysBridgePortAddressType for the entry to invalid(2)."
	INDEX	{ a3ComSysBridgePortAddressBridgeIndex, 
			a3ComSysBridgePortAddressPortIndex, 
			a3ComSysBridgePortAddressIndex }
::= { a3ComSysBridgePortAddressTable 1 }

A3ComSysBridgePortAddressEntry ::=
	SEQUENCE {
		a3ComSysBridgePortAddressBridgeIndex
			INTEGER,
		a3ComSysBridgePortAddressPortIndex
			INTEGER,
		a3ComSysBridgePortAddressIndex
			INTEGER,
		a3ComSysBridgePortAddressRemoteAddress
			OCTET STRING,
		a3ComSysBridgePortAddressType
			INTEGER,
		a3ComSysBridgePortAddressIsStatic
			INTEGER,
		a3ComSysBridgePortAddressStaticPort
			INTEGER,
		a3ComSysBridgePortAddressAge
			INTEGER
	}

a3ComSysBridgePortAddressBridgeIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the bridge identified by this entry,
			relative to this agent."
::= { a3ComSysBridgePortAddressEntry 1 }

a3ComSysBridgePortAddressPortIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the bridge port identified by this entry,
			within the bridge identified by this entry."
::= { a3ComSysBridgePortAddressEntry 2 }

a3ComSysBridgePortAddressIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of this address entry within the bridge address
			table for the bridge identified by this entry.  This index
			ranges from 1 to the corresponding value of
			a3ComSysBridgeAddressTableSize." 
::= { a3ComSysBridgePortAddressEntry 3 }

a3ComSysBridgePortAddressRemoteAddress OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE (6)) -- 6 octet address in "canonical" order
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"The remote MAC address detected on the bridge port
			identified by to this entry.  Setting this object results
			in an attempt to create a new entry in the table.  Since
			the value of a3ComSysBridgePortAddressIndex is determined
			automatically internal to the bridge, a set is only
			successful if the index value specified for
			a3ComSysBridgePortAddressIndex is zero.  A get-next
			using the values of a3ComSysBridgePortAddressTypeIndex and
			a3ComSysBridgePortAddressPortIndex can be used to determine the
			address index assigned to the newly added address entry."
::= { a3ComSysBridgePortAddressEntry 4 }

a3ComSysBridgePortAddressType OBJECT-TYPE
	SYNTAX INTEGER {
				valid(1),
				invalid(2)
			}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"This object, when read, always returns the value valid(1).
			Setting this object to invalid(2) will remove the
			corresponding address entry from the table."
::= { a3ComSysBridgePortAddressEntry 5 }

a3ComSysBridgePortAddressIsStatic OBJECT-TYPE
	SYNTAX	INTEGER {
				isStatic(1),
				isDynamic(2)
			}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"A value indicating whether this MAC address was
			statically configured or was dynamically learned.  Note
			that isStatic(1) it the only valid for set operations."
::= { a3ComSysBridgePortAddressEntry 6 }

a3ComSysBridgePortAddressStaticPort OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"If the corresponding value of the object 
			a3ComSysBridgePortAddressIsStatic is isStatic(1), this object
			indicates the local bridge port index (as reported by
			a3ComSysBridgePortLocalIndex) for which this address MAC was
			statically configured.  If the object
			a3ComSysBridgePortAddressIsStatic has the value isDynamic(2),
			the value of this object is 0."
::= { a3ComSysBridgePortAddressEntry 7 }

a3ComSysBridgePortAddressAge OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"This object indicates the time, in seconds, elapsed since
			a packet containing this address as a source was last seen
			on the bridge port identified by this entry."
::= { a3ComSysBridgePortAddressEntry 8 }

a3ComSysBridgeStpGroupAddress OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE (6)) -- 6 octet address in "canonical" order
	ACCESS  read-write
	STATUS  obsolete
	DESCRIPTION
			"Spanning tree bridge group address. The address cannot be 
			changed if the spanning tree is enabled (a3ComSysBridgeStpEnabled).
			This object can now be found under the a3ComSysBridgeTable 
			as a3ComSysBridgeSTPGroupAddress."
		::= { a3ComSysBridge 6 }

a3ComSysBridgeStpEnable OBJECT-TYPE
	SYNTAX  INTEGER {
				true(1),
				false(2)
			}
	ACCESS  read-write
	STATUS  obsolete
	DESCRIPTION
			"This object indicates if spanning tree bridge feature is
			enabled or disabled.  If enabled this value will equal true(1).
			This object can now be found under the a3ComSysBridgeTable 
			as a3ComSysBridgeSTPEnable."
::= { a3ComSysBridge 7 }

-- The Switching Systems MIB IP router group.  Implementation of this
-- group is mandatory for agents which manage IP router resources.
-- This group is reserved for future use.

-- The Switching Systems MIB networking monitoring group.  Implementation
-- of this group is manadatory for all agents which manage bridge
-- resources that support network monitoring.

-- The Switching Systems MIB network analyzer table.

a3ComSysNetworkAnalyzerTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysNetworkAnalyzerTableEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A list of analyzer entries.  A single entry exists in this
			list for each bridge port configured for an analyzer."
::= { a3ComSysNetworkMonitor 1 }

a3ComSysNetworkAnalyzerTableEntry OBJECT-TYPE
	SYNTAX	A3ComSysNetworkAnalyzerTableEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"An analyzer table entry contains information relating an
			analyzer port address to the bridge and port index for that
			analyzer.

			The effect of creating an entry for a particular port is
			to configure that port for monitoring.  A port which is
			configured for monitoring is no longer available for
			switching.  To create an entry, set the value of the
			a3ComSysNetworkAnalyzerStatus object for a non-existent instance
			to valid(1).  The value of the a3ComSysNetworkAnalyzerPhysicalAddress
			object for the new entry is filled in as a result of the
			creation.

			The effect of removing an entry for a particular port is to
			disable the port for monitoring.  The port is then available
			for switching.  To remove an entry, set the value of the
			corresponding instance of the a3ComSysNetworkAnalyzerStatus object
			to invalid(2)."
	INDEX	{ a3ComSysNetworkAnalyzerBridgeIndex,
			a3ComSysNetworkAnalyzerBridgePortIndex}
::= { a3ComSysNetworkAnalyzerTable 1 }

A3ComSysNetworkAnalyzerTableEntry ::=
	SEQUENCE {
		a3ComSysNetworkAnalyzerBridgeIndex
			INTEGER,
		a3ComSysNetworkAnalyzerBridgePortIndex
			INTEGER,
		a3ComSysNetworkAnalyzerPhysicalAddress
			OCTET STRING,
		a3ComSysNetworkAnalyzerStatus
			INTEGER
	}

a3ComSysNetworkAnalyzerBridgeIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the bridge relative to this agent where the
			analyzer identified by this entry is configured."
::= { a3ComSysNetworkAnalyzerTableEntry 1 }

a3ComSysNetworkAnalyzerBridgePortIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the port relative to the bridge identified by
			this entry where the analyzer identified by this entry is
			configured."
::= { a3ComSysNetworkAnalyzerTableEntry 2 }

a3ComSysNetworkAnalyzerPhysicalAddress OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE (6)) -- 6 octet address in "canonical" order
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The physical address of the bridge port identified by the
			corresponding values of a3ComSysNetworkAnalyzerBridgeIndex and
			a3ComSysNetworkAnayzerBridgePortIndex."
::= { a3ComSysNetworkAnalyzerTableEntry 3 }

a3ComSysNetworkAnalyzerStatus OBJECT-TYPE
	SYNTAX	INTEGER {
				valid(1),
				invalid(2)
			}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"The status of the entry.  Setting the value of a non-existent
			instance of this object to valid(1) attempts to add the
			corresponding entry to the table.  The effect of adding an
			entry to the table is to configure the port for monitoring and
			to disable it for switching.  Setting an existing instance of
			this object to invalid(2) attempts to remove the corresponding
			entry from the table.  The effect of removing an entry from
			the table is to disable the port for monitoring and to make
			available for switching."
::= { a3ComSysNetworkAnalyzerTableEntry 4 }

-- The Switching Systems MIB network port monitor table.

a3ComSysNetworkPortMonitorTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysNetworkPortMonitorTableEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A list of monitor port entries.  A single entry exists in
			this for each bridge port being monitored."
::= { a3ComSysNetworkMonitor 2 }

a3ComSysNetworkPortMonitorTableEntry OBJECT-TYPE
	SYNTAX	A3ComSysNetworkPortMonitorTableEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A port monitor table entry contains information relating a
			bridge port being monitored with the address of the analyzer
			which is being used to monitor the port.

			The effect of creating an entry for a particular port is to
			enable monitoring of that port by the analyzer specified.  To
			create an entry, set the value of the
			a3ComSysNetworkPortMonitorAnalyzerAddress object to the address of
			the network analyzer port.  This value should be the same as
			the value of the a3ComSysNetworkAnalyzerPhysicalAddress object for
			the analyzer.

			The effect of removing an entry for a particular port is to
			disable monitoring of that port.  To remove an entry, set the
			value of the corresponding instance of the
			a3ComSysNetworkPortMonitorStatus object to invalid(2)."
	INDEX	{ a3ComSysNetworkPortMonitorBridgeIndex,
			a3ComSysNetworkPortMonitorBridgePortIndex }
::= { a3ComSysNetworkPortMonitorTable 1 }

A3ComSysNetworkPortMonitorTableEntry ::=
	SEQUENCE {
		a3ComSysNetworkPortMonitorBridgeIndex
			INTEGER,
		a3ComSysNetworkPortMonitorBridgePortIndex
			INTEGER,
		a3ComSysNetworkPortMonitorAnalyzerAddress
			OCTET STRING,
		a3ComSysNetworkPortMonitorStatus
			INTEGER
	}

a3ComSysNetworkPortMonitorBridgeIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the bridge relative to this agent where the
			monitored port identified by this entry is located."
::= { a3ComSysNetworkPortMonitorTableEntry 1 }

a3ComSysNetworkPortMonitorBridgePortIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the port which is being monitored relative to
			the bridge identified by this entry."
::= { a3ComSysNetworkPortMonitorTableEntry 2 }

a3ComSysNetworkPortMonitorAnalyzerAddress OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE (6)) -- 6 octet address in "canonical" order
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"The physical address of the port where the analyzer,
			which is monitoring the port identified by this entry, is
			located.  Setting the value of a non-existent instance of
			this object attempts to add an entry to the table.  The effect
			of adding an entry to the table is to enable monitoring of the
			port by the analyzer specified.  Setting the value of an
			existing instance of this object will switch the monitored
			port to the new analyzer address."
::= { a3ComSysNetworkPortMonitorTableEntry 3 }

a3ComSysNetworkPortMonitorStatus OBJECT-TYPE
	SYNTAX	INTEGER {
				valid(1),
				invalid(2)
			}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"The status of the entry.  Setting an existing instance
			of this object to invalid(2) attempts to remove the
			corresponding entry from the table.  The effect of removing
			an entry from the table is to disable monitoring of the
			port."
::= { a3ComSysNetworkPortMonitorTableEntry 4 }

-- The Switching Systems MIB token ring port group.  Implementation of
-- this group is mandatory for agents which manage token ring port
-- resources.

a3ComSysTokenRingPortCount OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The count of token ring ports managed by this agent."
::= { a3ComSysTokenRingPort 1 }


-- The Switching Systems MIB token ring port table.

a3ComSysTokenRingPortTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysTokenRingPortEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A list of token ring port entries.  A single entry exists
			 in this list for each token ring port managed by this agent."
::= { a3ComSysTokenRingPort 2 }

a3ComSysTokenRingPortEntry OBJECT-TYPE
	SYNTAX	A3ComSysTokenRingPortEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
			"A token ring port entry contains information about a
			 particular token ring port managed by this agent."
	INDEX	{ a3ComSysTokenRingPortIndex }
::= { a3ComSysTokenRingPortTable 1 }

A3ComSysTokenRingPortEntry ::=
	SEQUENCE {
		a3ComSysTokenRingPortIndex			INTEGER,
		a3ComSysTokenRingPortIfIndex		INTEGER,
		a3ComSysTokenRingPortLabel			DisplayString,
		a3ComSysTokenRingPortInsertStatus	INTEGER,
		a3ComSysTokenRingPortType			INTEGER,
		a3ComSysTokenRingPortMode			INTEGER,
		a3ComSysTokenRingPortSpeed			INTEGER,
		a3ComSysTokenRingPortLineErrors	Counter,
		a3ComSysTokenRingPortBurstErrors	Counter,
		a3ComSysTokenRingPortACErrors		Counter,
		a3ComSysTokenRingPortAbortTransErrors	Counter,
		a3ComSysTokenRingPortInternalErrors	Counter,
		a3ComSysTokenRingPortLostFrameErrors	Counter,
		a3ComSysTokenRingPortReceiveCongestionErrors	Counter,
		a3ComSysTokenRingPortFrameCopiedErrors	Counter,
		a3ComSysTokenRingPortTokenErrors		Counter,
		a3ComSysTokenRingPortSoftErrors		Counter,
		a3ComSysTokenRingPortHardErrors		Counter,
		a3ComSysTokenRingPortTransmitBeacons	Counter,
		a3ComSysTokenRingPortLobeWires			Counter,
		a3ComSysTokenRingPortRemoves			Counter,
		a3ComSysTokenRingPortSingles			Counter,
		a3ComSysTokenRingPortFreqErrors		Counter,
		a3ComSysTokenRingPortRingStatus		INTEGER
	}

a3ComSysTokenRingPortIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The index of the token ring port identified by this entry,
		 relative to this agent."
::= { a3ComSysTokenRingPortEntry 1 }

a3ComSysTokenRingPortIfIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The value of the MIB-II ifIndex corresponding to the
			 token ring port identified by this entry."
::= { a3ComSysTokenRingPortEntry 2 }

a3ComSysTokenRingPortLabel OBJECT-TYPE
	SYNTAX	DisplayString (SIZE (0..31))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"An ASCII text string describing the token ring port
			 identified by this entry."
::= { a3ComSysTokenRingPortEntry 3 }

a3ComSysTokenRingPortInsertStatus OBJECT-TYPE
	SYNTAX	INTEGER {
			inserted(1),
			deinserted(2)
			}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The current value of the link status for the token ring port
		 identified by this entry."
	::= { a3ComSysTokenRingPortEntry 4 }

a3ComSysTokenRingPortType OBJECT-TYPE
	SYNTAX	INTEGER {
			rj45(1),
			other(2)
			}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"Specific port type description for the token ring port
			 identified by this entry."
::= { a3ComSysTokenRingPortEntry 5 }

a3ComSysTokenRingPortMode OBJECT-TYPE
	SYNTAX	INTEGER	{
			station(1),
			lobe(2)
			}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"The current mode of the port. The default mode (station) is
			used to connect a hub to the port.  Lobe mode is used to direct
			connect a Token Ring station into the port.  This selection
			can only be made on ports 1 and 2 of the module."
::= { a3ComSysTokenRingPortEntry 6 }

a3ComSysTokenRingPortSpeed OBJECT-TYPE
	SYNTAX	INTEGER {
			fourMegabit(1),
			sixteenMegabit(2),
			sixteenMegabitETR(3)
			}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
			"The current speed of the port. The default speed is
			 sixteenMegabit."
::= { a3ComSysTokenRingPortEntry 7 }

a3ComSysTokenRingPortLineErrors OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"This counter is incremented when a frame
		or token is copied or repeated by a
		station, the E bit is zero in the frame
		or token and one of the following
		conditions exists: 1) there is a
		non-data bit (J or K bit) between the SD
		and the ED of the frame or token, or
		2) there is an FCS error in the frame."
::= { a3ComSysTokenRingPortEntry 8 }

a3ComSysTokenRingPortBurstErrors OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
				"This counter is incremented when a station
				detects the absence of transitions for five
				half-bit timers (burst-five error)."
::= {  a3ComSysTokenRingPortEntry 9 }

a3ComSysTokenRingPortACErrors OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"This counter is incremented when a station
		receives an AMP or SMP frame in which A is
		equal to C is equal to 0, and then receives
		another SMP frame with A is equal to C is
		equal to 0 without first receiving an AMP
		frame. It denotes a station that cannot set
		the AC bits properly."
::= { a3ComSysTokenRingPortEntry 10 }

a3ComSysTokenRingPortAbortTransErrors OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"This counter is incremented when a station
		transmits an abort delimiter while
		transmitting."
::= { a3ComSysTokenRingPortEntry 11 }

a3ComSysTokenRingPortInternalErrors OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"This counter is incremented when a station
		recognizes an internal error."
::= { a3ComSysTokenRingPortEntry 12 }

a3ComSysTokenRingPortLostFrameErrors OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"This counter is incremented when a station
		is transmitting and its TRR timer expires.
		This condition denotes a condition where a
		transmitting station in strip mode does not
		receive the trailer of the frame before the
		TRR timer goes off."
::= { a3ComSysTokenRingPortEntry 13 }

a3ComSysTokenRingPortReceiveCongestionErrors OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"This counter is incremented when a station
		recognizes a frame addressed to its
		specific address, but has no available
		buffer space indicating that the station
		is congested."
::= { a3ComSysTokenRingPortEntry 14 }

a3ComSysTokenRingPortFrameCopiedErrors OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"This counter is incremented when a station
		recognizes a frame addressed to its
		specific address and detects that the FS
		field A bits are set to 1 indicating a
		possible line hit or duplicate address."
::= { a3ComSysTokenRingPortEntry 15 }

a3ComSysTokenRingPortTokenErrors OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"This counter is incremented when a station
		acting as the active monitor recognizes an
		error condition that needs a token
		transmitted."
::= { a3ComSysTokenRingPortEntry 16 }

a3ComSysTokenRingPortSoftErrors OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The number of Soft Errors the interface
		has detected. It directly corresponds to
		the number of Report Error MAC frames
		that this interface has transmitted.
		Soft Errors are those which are
		recoverable by the MAC layer protocols."
::= { a3ComSysTokenRingPortEntry 17 }

a3ComSysTokenRingPortHardErrors OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The number of times this interface has
		detected an immediately recoverable
		fatal error.  It denotes the number of
		times this interface is either
		transmitting or receiving beacon MAC
		frames."
::= { a3ComSysTokenRingPortEntry 18 }

a3ComSysTokenRingPortTransmitBeacons OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The number of times this interface has
		transmitted a beacon frame."
::= { a3ComSysTokenRingPortEntry 19 }

a3ComSysTokenRingPortLobeWires OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The number of times the interface has
		detected an open or short circuit in the
		lobe data path.  The adapter will be closed
		when this condition occurs."
::= { a3ComSysTokenRingPortEntry 20 }

a3ComSysTokenRingPortRemoves OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The number of times the interface has
		received a Remove Ring Station MAC frame
		request.  When this frame is received
		the interface will enter the close state."
::= { a3ComSysTokenRingPortEntry 21 }

a3ComSysTokenRingPortSingles OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The number of times the interface has
			sensed that it is the only station on the
			ring.  This will happen if the interface
			is the first one up on a ring, or if
			there is a hardware problem."
::= { a3ComSysTokenRingPortEntry 22 }


a3ComSysTokenRingPortFreqErrors OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  optional
	DESCRIPTION
		"The number of times the interface has
		detected that the frequency of the
		incoming signal differs from the expected
		frequency."
::= { a3ComSysTokenRingPortEntry 23 }

a3ComSysTokenRingPortRingStatus OBJECT-TYPE
	 SYNTAX  INTEGER
	 ACCESS  read-only
	 STATUS  mandatory
	 DESCRIPTION
				"The current interface status which can
				be used to diagnose fluctuating problems
				that can occur on token rings, after a
				station has successfully been added to
				the ring.
					Before an open is completed, this
				object has the value for the 'no status'
				condition.  This object is useful for
				debugging problems when the station
				can not even enter the ring.
					The object's value is a sum of
				values, one for each currently applicable
				condition.  The following values are
				defined for various conditions:
					 0 = No Problems detected
					32 = Ring Recovery
					64 = Single Station
				   256 = Remove Received
				   512 = reserved
				  1024 = Auto-Removal Error
				  2048 = Lobe Wire Fault
				  4096 = Transmit Beacon
				  8192 = Soft Error
				 16384 = Hard Error
				 32768 = Signal Loss
				131072 = no status, open not completed."
::= { a3ComSysTokenRingPortEntry 24 }

--
-- a3ComSysFtGroup file transfer mib
--	
-- The Switching Systems MIB file transfer table.
--

a3ComSysFtTable OBJECT-TYPE
	SYNTAX SEQUENCE OF A3ComSysFtTableEntry
	ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
				"A list of entries which describe file transfers."
::= { a3ComSysFtGroup 1 }

a3ComSysFtTableEntry OBJECT-TYPE
	SYNTAX A3ComSysFtTableEntry
	ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
			"A description of a particular file transfer entry."
		INDEX { a3ComSysFtIndex }
::= { a3ComSysFtTable 1 }

A3ComSysFtTableEntry ::=
		SEQUENCE {
		a3ComSysFtIndex				INTEGER,
		a3ComSysFtDirection			INTEGER,
		a3ComSysFtLocalStorageType		A3ComSysStorageType,
		a3ComSysFtLocalResourceType	A3ComSysResourceType,
		a3ComSysFtLocalResourceMask	A3ComSysResourceBitMask,
		a3ComSysFtLocalResourceAttribute	OBJECT IDENTIFIER,
		a3ComSysFtRemoteAddressType	A3ComSysAddressType,
		a3ComSysFtRemoteAddress		OCTET STRING,
		a3ComSysFtRemoteFileName		DisplayString,
		a3ComSysFtRemoteUserName		DisplayString,
		a3ComSysFtRemoteUserPassword	OCTET STRING,
		a3ComSysFtForceTransfer		INTEGER,
		a3ComSysFtBytesTransferred		Counter,
		a3ComSysFtStatus				INTEGER,
		a3ComSysFtDetailedStatus		OBJECT IDENTIFIER,
		a3ComSysFtDetailedStatusString	DisplayString,
		a3ComSysFtOwnerString			DisplayString,
		a3ComSysFtRowStatus			RowStatus
		}

a3ComSysFtIndex OBJECT-TYPE
	SYNTAX INTEGER (1..65535)
	ACCESS read-only
	STATUS mandatory
		DESCRIPTION
				"A unique index used to identifying this entry."
::= { a3ComSysFtTableEntry 1 }

a3ComSysFtDirection OBJECT-TYPE
	SYNTAX INTEGER {
			localToRemote(1),
			remoteToLocal(2)
		}
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
			"Specifies the direction of the file transfer."
	DEFVAL { remoteToLocal }    
::= { a3ComSysFtTableEntry 2 }

a3ComSysFtLocalStorageType OBJECT-TYPE
	SYNTAX A3ComSysStorageType
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
			"The type of storage on the local system to be
			used as the source/destination for the file transfer."
	DEFVAL { 3 }   --storageFlashMemory     
::= { a3ComSysFtTableEntry 3 }

a3ComSysFtLocalResourceType OBJECT-TYPE
	SYNTAX A3ComSysResourceType
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
			"The type of resource on the local system to be
			used as the source/destination for the file transfer."
	DEFVAL { 2 }    -- resourceSystem
::= { a3ComSysFtTableEntry 4 }

a3ComSysFtLocalResourceMask OBJECT-TYPE
	SYNTAX A3ComSysResourceBitMask
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
			"The indices of the resources on the local system to
			be used as the source/destination for the file transfer.
			The type of resource to which these indices apply is
			specified by the corresponding value of
			a3ComSysFtLocalResourceType. If resourceBridge is used,
			a3ComSysFtLocalResourceMask indicates the bridge slot
			number the filter code will be downloaded.
			For instance, a3ComSysFtLocalResourceMask value of 0x03
			indicates bridge slot number 1 and 2."
	DEFVAL { 128 }    
::= { a3ComSysFtTableEntry 5 }

a3ComSysFtLocalResourceAttribute OBJECT-TYPE
	SYNTAX OBJECT IDENTIFIER
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
			"An identifier which specifies the particular resource
			attribute on the local system which is the source/destination
			of the file transfer. The resource(s) to which this attribute
			applies is specified by the corresponding values of
			a3ComSysFtLocalResourceType and a3ComSysFtLocalResourceMask."
	DEFVAL { a3ComSysFtSystemOperationalCode }    
::= { a3ComSysFtTableEntry 6 }

a3ComSysFtRemoteAddressType OBJECT-TYPE
	SYNTAX A3ComSysAddressType
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
			"The type of address which is specified by the corresponding
			value of a3ComSysFtRemoteAddress."
DEFVAL { 2 }  --addrIp    
::= { a3ComSysFtTableEntry 7 }

a3ComSysFtRemoteAddress OBJECT-TYPE
	SYNTAX OCTET STRING (SIZE (0..32))
	ACCESS read-write	
	STATUS mandatory
	DESCRIPTION
				"The address of the source/destination file on the remote
				system."
	::= { a3ComSysFtTableEntry 8 }

a3ComSysFtRemoteFileName OBJECT-TYPE
	SYNTAX DisplayString (SIZE (0..128))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
				"The full path name of the source/destination file on the
				remote system."
::= { a3ComSysFtTableEntry 9 }

a3ComSysFtRemoteUserName OBJECT-TYPE
	SYNTAX DisplayString (SIZE (0..128))
   	ACCESS read-write
   	STATUS mandatory
   	DESCRIPTION
          		"The user name to be used when requesting the file transfer
           		to/from the remote system."
::= { a3ComSysFtTableEntry 10 }

a3ComSysFtRemoteUserPassword OBJECT-TYPE
	SYNTAX OCTET STRING (SIZE (0..128))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The password to be used when requesting the file transfer
		to/from the remote system. When read, this object returns
		a zero length string. Note that, for security reasons,
		some ftp servers may insist on a non-zero length user password."
::= { a3ComSysFtTableEntry 11 }

a3ComSysFtForceTransfer OBJECT-TYPE
	SYNTAX INTEGER {
		true(1),
		false(2)
	}
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Setting this object to true makes the agent ignore
		non-fatal (i.e. version/id mismatch) errors encountered 
		during a file transfer request."
	DEFVAL { false }    
::= { a3ComSysFtTableEntry 12 }

a3ComSysFtBytesTransferred OBJECT-TYPE
	SYNTAX Counter
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The number of bytes successfully transferred."
::= { a3ComSysFtTableEntry 13 }

a3ComSysFtStatus OBJECT-TYPE
	SYNTAX INTEGER {
		statusSuccessfulCompletion(1),
		statusInProgress(2),
		statusLocalInvalid(3),
		statusRemoteInvalid(4),
		statusRemoteUnreachable(5),
		statusUserAuthFailed(6),
		statusFileNotFound(7),
		statusFileTooBig(8),
		statusFileIncompatible(9),
		statusError(10)
	}
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The status of the file transfer."
::= { a3ComSysFtTableEntry 14 }

a3ComSysFtDetailedStatus OBJECT-TYPE
	SYNTAX OBJECT IDENTIFIER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Detailed status for the transfer for the particular 
		local resource attribute specified by the corresponding
		values of a3ComSysFtLocalStorageType, a3ComSysFtLocalResourceType,
		a3ComSysFtLocalResourceMask, and a3ComSysFtLocalResourceAttribute.

		Note that this object is only valid in the case where
		a3ComSysFtStatus indicates an error."
::= { a3ComSysFtTableEntry 15 }

a3ComSysFtDetailedStatusString OBJECT-TYPE
	SYNTAX DisplayString
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Detailed status description for the requested transfer."
::= { a3ComSysFtTableEntry 16 }

a3ComSysFtOwnerString OBJECT-TYPE
	SYNTAX DisplayString (SIZE (0..128))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"A string describing the creator/owner of this entry."
::= { a3ComSysFtTableEntry 17 }

a3ComSysFtRowStatus OBJECT-TYPE
	SYNTAX RowStatus
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The row status object controls the creation/deletion of rows
		in this table. Its semantics are the same as those for the
		RowStatus textual convention specified for SNMPv2. 

		Setting this object to createAndGo(4) is not allowed.

		Setting this object to createAndWait(5) causes an entry
		to be created with a3ComSysFtRowStatus value of notReady(3).
	
		Setting this object to active(1) causes the transfer to
		start for the given row. Objects within the row cannot 
		be modified once a row has been set to active(1),

		Setting this object to destroy(6) causes the corresponding
		row to be deleted.
		
		Note that a request to set a row to notInService(2) or 
		destroy(6) will fail if the current rowStatus value is active(1)
		(i.e. a file transfer is currently in progress). This is
		necessary since aborting a file transfer may leave the
		system in an inconsistent state.

		Note that, currently, only a single instance of a row 
		can be created in this table."
::= { a3ComSysFtTableEntry 18 }


 -- File transfer resource attributes.

a3ComSysFtResourceAttributes OBJECT IDENTIFIER ::= { a3ComSysFtGroup 2 }


-- File transfer resource attributes groups.

a3ComSysFtSystemAttributes        OBJECT IDENTIFIER ::= { a3ComSysFtResourceAttributes 1 }


-- File transfer system resource attributes.

a3ComSysFtSystemOperationalCode  OBJECT IDENTIFIER ::= { a3ComSysFtSystemAttributes 1 }
a3ComSysFtSystemConfiguration    OBJECT IDENTIFIER ::= { a3ComSysFtSystemAttributes 2 }

-- File transfer bridge resource attributes

a3ComSysFtSystemBridgeFilterCode OBJECT IDENTIFIER ::= { a3ComSysFtSystemAttributes 3 }

-- File transfer detailed resource status.

a3ComSysFtDetailedResourceStatus OBJECT IDENTIFIER ::= { a3ComSysFtGroup 3 }


-- File transfer detailed resource status groups.

a3ComSysFtSystemDetailedStatus   OBJECT IDENTIFIER ::= { a3ComSysFtDetailedResourceStatus 1 }

-- File transfer system detailed status.

a3ComSysFtSysStatusNotApplicable OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 1 }
a3ComSysFtSysStatusNoImageLabel  OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 2 }
a3ComSysFtSysStatusConfigIdMismatch OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 3 }
a3ComSysFtSysStatusChecksumError OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 4 }
a3ComSysFtSysStatusNvRamError    OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 5 }
a3ComSysFtSysStatusFlashError    OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 6 }
a3ComSysFtSysStatusNoRoom        OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 7 }

-- File transfer bridge detailed status

a3ComSysFtSysBridgeFilterNotApplicable   OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 8 }
a3ComSysFtSysBridgeFilterSyntaxError     OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 9 }
a3ComSysFtSysBridgeFilterdownloadError   OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 10 }
a3ComSysFtSysBridgeFilterNoRoom          OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 11 }

--
-- IP Group
--

-- The a3ComSysIpBaseGroup is resreved for future use

a3ComSysIpBaseGroup			OBJECT IDENTIFIER ::= { a3ComSysIpGroup 1 }
a3ComSysIpInterfaceGroup		OBJECT IDENTIFIER ::= { a3ComSysIpGroup 2 } 

a3ComSysIpInterfaceCount OBJECT-TYPE 
	SYNTAX  INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"A count of the total number of IP interfaces configured."
::= { a3ComSysIpInterfaceGroup 1 }

a3ComSysIpInterfaceTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysIpInterfaceEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A list of configured IP interfaces."
::= { a3ComSysIpInterfaceGroup 2 }

a3ComSysIpInterfaceEntry OBJECT-TYPE
	SYNTAX	A3ComSysIpInterfaceEntry
	ACCESS	not-accessible	
	STATUS	mandatory
	DESCRIPTION
		"An individual IP interface."
	INDEX	{ a3ComSysIpInterfaceIpStackIndex, a3ComSysIpInterfaceAddr, a3ComSysIpInterfaceNetMask }
::= { a3ComSysIpInterfaceTable 1 }

A3ComSysIpInterfaceEntry	::= SEQUENCE {
	a3ComSysIpInterfaceIpStackIndex  INTEGER,
	a3ComSysIpInterfaceAddr		  IpAddress,
	a3ComSysIpInterfaceNetMask		  IpAddress,
	a3ComSysIpInterfaceIndex		  INTEGER,
	a3ComSysIpInterfaceBcastAddr	  INTEGER,
	a3ComSysIpInterfaceCost		  INTEGER,
	a3ComSysIpInterfaceStatus        RowStatus
}

a3ComSysIpInterfaceIpStackIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the IP stack identified by this entry
			relative to this agent."
::= { a3ComSysIpInterfaceEntry 1 }

a3ComSysIpInterfaceAddr OBJECT-TYPE
	SYNTAX	IpAddress	
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The IP address of this entry within the IP stack identified
		within this entry."
::= { a3ComSysIpInterfaceEntry 2 }

a3ComSysIpInterfaceNetMask OBJECT-TYPE
	SYNTAX	IpAddress
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The subnet mask associated with this IP interface.  The value of the mask 
		is an IP address with all the network bits set to 1 and all the host bits
		set to 0."
::= { a3ComSysIpInterfaceEntry 3 }

a3ComSysIpInterfaceIndex OBJECT-TYPE
	SYNTAX	INTEGER	
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The index value which uniquely identifies the interface
		to which this entry is applicable.  lspIPInterfaceIndex maps to
		the same interface as identified by ifIndex in the ifTable.  Currently,
		this object can not be modified after creation."
	::= { a3ComSysIpInterfaceEntry 4 }

a3ComSysIpInterfaceBcastAddr OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"This object represents the value of the least significant
		bit of this entry's direct broadcast address.  For example,
		a value of one signifies that the host portion of the broadcast
		address is set to all ones."
	DEFVAL	{ 1 }
::= { a3ComSysIpInterfaceEntry 5 }

a3ComSysIpInterfaceCost OBJECT-TYPE
	SYNTAX	INTEGER ( 1..15 )
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The route cost metric used for this entry."
	DEFVAL	{ 1 }
::= { a3ComSysIpInterfaceEntry 6 }

a3ComSysIpInterfaceStatus OBJECT-TYPE
	SYNTAX  RowStatus	
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The status column for this IP interface.  This object can be set to:
		createAndGo(4)
		destroy(6)

		The following value may be read:
		active(1)

		Setting this object to createAndGo(4) causes the agent to
		attempt to create and commit the row based on the contents
		of the object in the row.  If all necessary information is
		present in the row and the values are acceptable to the
		agent, the agent will change the status to active(1).  If any
		of the necessary objects are not available the agent
		will reject the request.

		Other objects in this row entry can be individually modified
		while the row status is active(1).

		Setting this object to destroy(6) will remove this entry."
::= { a3ComSysIpInterfaceEntry 7 }

-- 
-- The IPX Group
--

a3ComSysIpxBaseGroup		OBJECT IDENTIFIER ::= { a3ComSysIpxGroup 1 }
a3ComSysIpxInterfaceGroup	OBJECT IDENTIFIER ::= { a3ComSysIpxGroup 2 }

a3ComSysIpxInterfaceCount OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"A count of the total number of IPX interfaces configured."
::= { a3ComSysIpxInterfaceGroup 1 }

a3ComSysIpxInterfaceTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF A3ComSysIpxInterfaceEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A list of configured IPX interfaces."
::= { a3ComSysIpxInterfaceGroup 2 }

a3ComSysIpxInterfaceEntry OBJECT-TYPE
	SYNTAX	A3ComSysIpxInterfaceEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"An individual IPX interface."
	INDEX	{ a3ComSysIpxInterfaceIpxStackIndex, a3ComSysIpxInterfaceNetNumber }
::= { a3ComSysIpxInterfaceTable 1 }

A3ComSysIpxInterfaceEntry ::= SEQUENCE {
	a3ComSysIpxInterfaceIpxStackIndex  INTEGER,
	a3ComSysIpxInterfaceNetNumber	    IpxNetworkNumber,
	a3ComSysIpxInterfaceIfIndex		INTEGER,
	a3ComSysIpxInterfaceCost		    INTEGER,
	a3ComSysIpxInterfaceFrameType	    INTEGER,
	a3ComSysIpxInterfaceStatus		    RowStatus
}

a3ComSysIpxInterfaceIpxStackIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
			"The index of the IPX stack identified by this entry
			relative to this agent."
::= { a3ComSysIpxInterfaceEntry 1 }

a3ComSysIpxInterfaceNetNumber OBJECT-TYPE
	SYNTAX	IpxNetworkNumber
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The IPX Network Number of this entry."
::= { a3ComSysIpxInterfaceEntry 2 }

a3ComSysIpxInterfaceIfIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The ifIndex of the virtual interface that this IPX interface is
		is configured over.  The a3ComSysIpxInterfaceIfIndex identifies a
		virtual interface, for example a VLAN, that this local address 
		is associated with for purposes of routing or network management." 
::= { a3ComSysIpxInterfaceEntry 3 }

a3ComSysIpxInterfaceCost OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The cost associated with the IPX address of this entry."
	DEFVAL	{ 1 }
::= { a3ComSysIpxInterfaceEntry 4 }	

a3ComSysIpxInterfaceFrameType OBJECT-TYPE
	SYNTAX	INTEGER {
			frame-ethernetII(1),
			frame-802-2(2),
			frame-802-3-Raw(3),
			frame-SNAP(4)
		}
	ACCESS	read-write
	STATUS mandatory
	DESCRIPTION
		"The frame format used for routing frames on this IPX interface.  The framing
		formats are for ethernet ports.  There are two frame formats for FDDI ports:
		802.2 and FDDI SNAP.  The correct FDDI format is automatically chosen if 
		this interface is associated with a VLAN interface that contains both ethernet
		and FDDI ports.  If the VLAN interface is an FDDI port, than the only
		values that can be written to this object are: frame-802-2(2) and
		frame-SNAP(4). " 
::= { a3ComSysIpxInterfaceEntry 5 }

a3ComSysIpxInterfaceStatus OBJECT-TYPE
	SYNTAX  RowStatus	
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The status column for this IPX interface.  This OBJECT can be set to:
		createAndGo(4)
		destroy(6)

		The following value may be read:
		active(1)

		Setting this object ot createAndGo(4) causes the agent to
		attempt to create and commit the row based on the contents
		of the object in the row.  If all necessary information is
		present in the row and the values are acceptable to the
		agent, the agent will change the status to active(1).  If any
		of the necessary objects are not available the agent
		will reject the request.

		Other objects in this row entry can be individually modified
		while the row status is active(1).

		Setting this object to destroy(6) will remove this entry."
::= { a3ComSysIpxInterfaceEntry 6 }

--
-- The Apple Talk Group
--

a3ComSysAppleTalkBaseGroup         OBJECT IDENTIFIER ::= { a3ComSysAppleTalkGroup 1 }
a3ComSysAppleTalkInterfaceGroup    OBJECT IDENTIFIER ::= { a3ComSysAppleTalkGroup 2 }

-- The AppleTalkInterace Group
--
-- Implementation of this group is mandatory for all entities
-- that implement AppleTalk ports

a3ComSysAtInterfaceCount OBJECT-TYPE 
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"A count of the total number of AppleTalk interfaces configured."
::= { a3ComSysAppleTalkInterfaceGroup 1 }

a3ComSysAtInterfaceTable OBJECT-TYPE
	SYNTAX SEQUENCE OF A3ComSysAtInterfaceEntry
	ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
		"A list of AppleTalk ports for this entity."
::= { a3ComSysAppleTalkInterfaceGroup 2 }

a3ComSysAtInterfaceEntry OBJECT-TYPE
	SYNTAX A3ComSysAtInterfaceEntry
	ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
		"An individual appletalk interface entry.
		Appletalk entries with row status of active(1)
		cannot be modified but must set to destroy(6)
		and recreated."
	INDEX { a3ComSysAtInterfaceAtStackIndex, a3ComSysAtInterfaceIfIndex }
::= { a3ComSysAtInterfaceTable 1 }

A3ComSysAtInterfaceEntry ::= SEQUENCE {
		a3ComSysAtInterfaceAtStackIndex       	INTEGER,
		a3ComSysAtInterfaceNetAddress         	DdpNodeAddress,
		a3ComSysAtInterfaceType               	INTEGER,
		a3ComSysAtInterfaceNetStart           	ATNetworkNumber,
		a3ComSysAtInterfaceNetEnd             	ATNetworkNumber,
		a3ComSysAtInterfaceZoneDefault  	    ATName,
		a3ComSysAtInterfaceZone1               ATName,
		a3ComSysAtInterfaceZone2               ATName,
		a3ComSysAtInterfaceZone3               ATName,
		a3ComSysAtInterfaceZone4               ATName,
		a3ComSysAtInterfaceZone5               ATName,
		a3ComSysAtInterfaceZone6               ATName,
		a3ComSysAtInterfaceZone7               ATName,
		a3ComSysAtInterfaceZone8               ATName,
		a3ComSysAtInterfaceZone9               ATName,
		a3ComSysAtInterfaceZone10              ATName,
		a3ComSysAtInterfaceZone11              ATName,
		a3ComSysAtInterfaceZone12              ATName,
		a3ComSysAtInterfaceZone13              ATName,
		a3ComSysAtInterfaceZone14              ATName,
		a3ComSysAtInterfaceZone15              ATName,
		a3ComSysAtInterfaceIfIndex		        INTEGER,  
		a3ComSysAtInterfaceState              	INTEGER,
		a3ComSysAtInterfaceStatus            	RowStatus
}

a3ComSysAtInterfaceAtStackIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The index of the Appletalk stack identified by this entry
		relative to this agent.

		Setting of this object is required for all interface creations."
::= { a3ComSysAtInterfaceEntry 1 }

a3ComSysAtInterfaceNetAddress OBJECT-TYPE
	SYNTAX DdpNodeAddress
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The AppleTalk network address configured for this
		port."
::= { a3ComSysAtInterfaceEntry 2 }

a3ComSysAtInterfaceType OBJECT-TYPE
	SYNTAX INTEGER {
					seedInterface(1), 
					nonseedInterface(2)
				   }
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The type of interface that is configured for this port.
		Setting of this object is required for all interface creations."
::= { a3ComSysAtInterfaceEntry 3 }

a3ComSysAtInterfaceNetStart OBJECT-TYPE
	SYNTAX ATNetworkNumber
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The first AppleTalk network address in the range
		configured for this port.  If this port is not a
		native AppleTalk port, this object shall have the
		value of two octets of zero.
		Setting of this object is mandatory only for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 4 }

a3ComSysAtInterfaceNetEnd OBJECT-TYPE
	SYNTAX ATNetworkNumber
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The last AppleTalk network address in the range
		configured for this port.  If the network to which
		this AppleTalk port is connected is a non-extended
		network, or if it is not a native AppleTalk port,
		the value for a3ComSysAtInterfaceNetEnd shall be two octets of
		zero.

		Setting of this object is mandatory only for
		interfaces with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 5 }


a3ComSysAtInterfaceZoneDefault OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The name of the default zone for this port.  If
		this port only has one zone, that zone is
		represented here.

		Setting of this object is mandatory for
		interfaces with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 6 }

a3ComSysAtInterfaceZone1 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 7 }

a3ComSysAtInterfaceZone2 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 8 }

a3ComSysAtInterfaceZone3 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 9 }

a3ComSysAtInterfaceZone4 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 10 }

a3ComSysAtInterfaceZone5 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 11 }

a3ComSysAtInterfaceZone6 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 12 }

a3ComSysAtInterfaceZone7 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 13 }

a3ComSysAtInterfaceZone8 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 14 }

a3ComSysAtInterfaceZone9 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 15 }

a3ComSysAtInterfaceZone10 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 16 }

a3ComSysAtInterfaceZone11 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 17 }

a3ComSysAtInterfaceZone12 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 18 }

a3ComSysAtInterfaceZone13 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 19 }

a3ComSysAtInterfaceZone14 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 20 }

a3ComSysAtInterfaceZone15 OBJECT-TYPE
	SYNTAX ATName
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Zone name in this entry's zone list.

		This object may only only be set for interfaces
		with a3ComSysAtInterfaceType equal to seedInterface(1)."
::= { a3ComSysAtInterfaceEntry 21 }


a3ComSysAtInterfaceIfIndex OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The  interface associated with this
		AppleTalk port.  The interface identified by a
		particular value of this index is the same interface
		as identified by the same value of ifIndex in the ifTable.

		Setting of this object is required for all interface creations."
::= { a3ComSysAtInterfaceEntry 22 }

a3ComSysAtInterfaceState OBJECT-TYPE
	SYNTAX INTEGER {
					unused(1),
					initialize(2),
					terminate(3),
					failed(4),
					down(5),
					validate(6),
					discover(7),
					waiting(8),
					enabled(9)
					}
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
				"The current state of the appletalk interface."
::= { a3ComSysAtInterfaceEntry 23 }

a3ComSysAtInterfaceStatus OBJECT-TYPE
	SYNTAX RowStatus
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The status column for this IP interface.  This object can be set to:
		createAndGo(4)
		createAndWait(5)
		destroy(6)

		The following value may be read:
		active(1)
		notInService(2)

		Setting this object to createAndGo(4) causes the agent to
		attempt to create and commit the row based on the contents
		of the object in the row.  If all necessary information is
		present in the row and the values are acceptable to the
		agent, the agent will change the status to active(1).  If any
		of the necessary objects are not available the agent
		will reject the request.

		Setting this object to createAndWait(5) causes the agent to
		create an entry which has the value notInService(2).  Only three
		notInService(2) entries are permitted at any one time.
		Setting a row with status notInService(2) to active(1) 
		will cause this entry to change to active(1) if the
		appropriate columns have been set.

		Setting this object to destroy(6) will remove this entry."
::= { a3ComSysAtInterfaceEntry 24 }


-- The A3ComSys Module Card group.  Implementation of this
-- group is mandatory for agents which manage system resources for
-- systems with modular components.

a3ComSysModuleCardCount OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The current count of module components present in the
		system."
::= { a3ComSysModuleCardGroup 1 }


-- The A3ComSys Module Card information table.

a3ComSysModuleCardInfoTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF A3ComSysModuleCardInfoEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION
		"A list of module card information entries.  A single entry exists in
		this list for each modular component in the system."
::= { a3ComSysModuleCardGroup 2 }

a3ComSysModuleCardInfoEntry OBJECT-TYPE
	SYNTAX  A3ComSysModuleCardInfoEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION
			"A module card info entry contains information about a
			particular modular component within the system."
	INDEX   { a3ComSysModuleCardInfoIndex }
::= { a3ComSysModuleCardInfoTable 1 }

A3ComSysModuleCardInfoEntry ::=
	SEQUENCE {
		a3ComSysModuleCardInfoIndex
			INTEGER,
		a3ComSysModuleCardInfoFamily
			INTEGER,
		a3ComSysModuleCardInfoGenericType
			INTEGER,
		a3ComSysModuleCardInfoSpecificType
			INTEGER,
		a3ComSysModuleCardInfoPartNumber
			DisplayString,
		a3ComSysModuleCardInfoManufacturingDate
			DisplayString,
		a3ComSysModuleCardInfoModuleSerialNumber
			DisplayString,
		a3ComSysModuleCardInfoTLASerialNumber
			DisplayString,
		a3ComSysModuleCardInfo3CNumber
			DisplayString,
		a3ComSysModuleCardInfoICTTestStatus
			INTEGER,
		a3ComSysModuleCardInfoICTTestRevision
			DisplayString,
		a3ComSysModuleCardInfoSystemTestStatus
			INTEGER,
		a3ComSysModuleCardInfoFunctionalTestStatus
			INTEGER,
		a3ComSysModuleCardInfoFunctionalTestRevision
			DisplayString,
		a3ComSysModuleCardInfoBoardRevision
			DisplayString,
		a3ComSysModuleCardInfoRuntimeHours
			INTEGER
	}

a3ComSysModuleCardInfoIndex OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The index of the modular component identified by this
			entry."
::= { a3ComSysModuleCardInfoEntry 1 }

a3ComSysModuleCardInfoFamily OBJECT-TYPE
	SYNTAX  INTEGER {
				coreBuilder3500(1),
				superStack7000(2),
				superStack9000(3),

				coreBuilder9000-RF12R(17),
				coreBuilder9000-RF6MC(18),
				coreBuilder9000-LF20R(19),
				coreBuilder9000-LF10MC(20),
				coreBuilder9000-LF36T(21),
				coreBuilder9000-FG24(22),
				coreBuilder9000-FG9(23),
				coreBuilder9000-LG9MC(24),
				coreBuilder9000-LG9(25)
			}
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The family code for this module."
::= { a3ComSysModuleCardInfoEntry 2 }

a3ComSysModuleCardInfoGenericType OBJECT-TYPE
	SYNTAX  INTEGER {
				backplaneOrMotherboard(1),
				processorBoard(2),
				enet10MbAnd100MbAdaptor(3),
				enet1GbAdaptor(4),
				fddiAdaptor(5),
				atmAdaptor(6)
			}

	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The generic type code for this module."
::= { a3ComSysModuleCardInfoEntry 3 }

a3ComSysModuleCardInfoSpecificType OBJECT-TYPE
	SYNTAX  INTEGER {
				notApplicable(1),
				atmSonetOC3Fiber(161),
				atmSonetOC12Fiber(162),
				atmSonetOC3Copper(163),
				atmSonetOC12Copper(164),

				enet1Gb850nMMultimodeFiber(177),
				enet1Gb1300nMFiber(178),
				enet1GbCoax(179),
				packetSwitchingFabric1000BaseBackplane(180), 
				enet1Gb1000BaseTx(181),
				enet1000BaseSxMmfSCandGBIC(183),

				enet100Mb100BaseTx(225),
				enet10or100BaseTxTelco(226),
				enet100Mb100BaseFx(227),
				enet100Mb100BaseT4(228),
				enet100Mb100BaseTxSTP(229),
				enet100Mb100BaseT2(230),

				fddiMultimodeSC(241),
				fddiSingleModeSC(242),
				fddiCopperUTP(243),
				fddiCopperSTP(244)
			}
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The specific type code for this module."
::= { a3ComSysModuleCardInfoEntry 4 }

a3ComSysModuleCardInfoPartNumber OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The specific part number for this module."
::= { a3ComSysModuleCardInfoEntry 5 }

a3ComSysModuleCardInfoManufacturingDate OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The date that this module was manufactured in the
			format mm/dd/yyyy."
::= { a3ComSysModuleCardInfoEntry 6 }

a3ComSysModuleCardInfoModuleSerialNumber OBJECT-TYPE
	SYNTAX  DisplayString (SIZE(12))
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"3Com serial number."
::= { a3ComSysModuleCardInfoEntry 7 }

a3ComSysModuleCardInfoTLASerialNumber OBJECT-TYPE
	SYNTAX  DisplayString (SIZE(12))
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"TOP level assembly serial number for boards with
	non-removable daughter cards. Null string for
	all other board types."
::= { a3ComSysModuleCardInfoEntry 8 }

a3ComSysModuleCardInfo3CNumber OBJECT-TYPE
	SYNTAX  DisplayString (SIZE(10))
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"On a backplane or non-removable module this is the
			3C number of the chassis. On a removable module this
			is the 3C number of the module."
::= { a3ComSysModuleCardInfoEntry 9 }

a3ComSysModuleCardInfoICTTestStatus OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"1 equals test passed, or greater than 1 identifies the
			test number failure (0 or FF indicates field yet not
			written)."
::= { a3ComSysModuleCardInfoEntry 10 }

a3ComSysModuleCardInfoICTTestRevision OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"Manufacturing ATE test revision number (XX.XX)."
::= { a3ComSysModuleCardInfoEntry 11 }

a3ComSysModuleCardInfoSystemTestStatus OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"1 equals test passed, or greater than 1 identifies the
			test number failure (0 or FF indicates field yet not
			written)."
::= { a3ComSysModuleCardInfoEntry 12 }

a3ComSysModuleCardInfoFunctionalTestStatus OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"1 equals test passed, or greater than 1 identifies the
			test number failure (0 or FF indicates field yet not
			written)."
::= { a3ComSysModuleCardInfoEntry 13 }

a3ComSysModuleCardInfoFunctionalTestRevision OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"Manufacturing functional test revision number (XX.XX)."
::= { a3ComSysModuleCardInfoEntry 14 }

a3ComSysModuleCardInfoBoardRevision OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"Board revision code. "
::= { a3ComSysModuleCardInfoEntry 15 }

a3ComSysModuleCardInfoRuntimeHours OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"A total count of the number of hours this module has
			been in operation."
::= { a3ComSysModuleCardInfoEntry 16 }



-- The A3ComSys Diagnostics group.  Implementation of this
-- group is mandatory for agents which manage system resources for
-- systems with modular components.


-- The A3ComSys Diagnostics event information table.  Each PI-ROM maintains
-- its own last diagnostic event information, hence they are tabularized
-- separately.

a3ComSysDiagnosticsInfoTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF A3ComSysDiagnosticsInfoEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION
			"A list of module card information entries.  A single entry exists in
			this list for each modular component in the system."
::= { a3ComSysDiagnosticsGroup 1 }

a3ComSysDiagnosticsInfoEntry OBJECT-TYPE
	SYNTAX  A3ComSysDiagnosticsInfoEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION
			"A diagnostics info entry contains information about a particular
			 diagnostics event on a modular component within the system."
	INDEX   { a3ComSysDiagnosticsInfoIndex }
::= { a3ComSysDiagnosticsInfoTable 1 }

A3ComSysDiagnosticsInfoEntry ::=
	SEQUENCE {
		a3ComSysDiagnosticsInfoIndex
			INTEGER,
		a3ComSysDiagnosticsInfoPOVDiagnosticsRevision
			DisplayString,
		a3ComSysDiagnosticsInfoExtendedDiagnosticsRevision
			DisplayString,
		a3ComSysDiagnosticsInfoDiagnosticFailureCode
			DisplayString,
		a3ComSysDiagnosticsInfoDiagnosticFailureDateTime
			DisplayString,
		a3ComSysDiagnosticsInfoDiagnosticFailureSlotNumber
			INTEGER,
		a3ComSysDiagnosticsInfoDiagnosticFailureCounter
			INTEGER,
		a3ComSysDiagnosticsInfoDiagnosticFieldDOACounter
			INTEGER
	}

a3ComSysDiagnosticsInfoIndex OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The index of the diagnostics modular component identified by this
			 entry."
::= { a3ComSysDiagnosticsInfoEntry 1 }

a3ComSysDiagnosticsInfoPOVDiagnosticsRevision OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The revision of the POV (power on verification) diagnostics
		 software at the most recent failure."
::= { a3ComSysDiagnosticsInfoEntry 2 }

a3ComSysDiagnosticsInfoExtendedDiagnosticsRevision OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The revision of the extended diagnostics software at the
		 most recent failure."
::= { a3ComSysDiagnosticsInfoEntry 3 }

a3ComSysDiagnosticsInfoDiagnosticFailureCode OBJECT-TYPE
	SYNTAX	DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The code written by the diagnostics at the most recent
			 failure.  This identifies both the test number and failure 
			 code in the following format:  <testNumber>-<errorCode>.
			 If there is no failure then 000-000 is displayed."
::= { a3ComSysDiagnosticsInfoEntry 4 }

a3ComSysDiagnosticsInfoDiagnosticFailureDateTime OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The date and time of the most recent diagnostic failure
			 for the module."
::= { a3ComSysDiagnosticsInfoEntry 5 }

a3ComSysDiagnosticsInfoDiagnosticFailureSlotNumber OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The slot number (network adapter cards only) of the most
			 recent diagnostic failure for the module."
::= { a3ComSysDiagnosticsInfoEntry 6 }

a3ComSysDiagnosticsInfoDiagnosticFailureCounter OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The total number of diagnostic failures logged against this
			 module."
::= { a3ComSysDiagnosticsInfoEntry 7 }

a3ComSysDiagnosticsInfoDiagnosticFieldDOACounter OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
			"The total number of failures occurring at this module during
			 the first 48 hours of operation."
	::= { a3ComSysDiagnosticsInfoEntry 8 }

--
-- The Switching Systems MIB traps.
--

a3ComSysSystemOverTemperatureEvent TRAP-TYPE
	ENTERPRISE	switchingSystemsMibGroups
	VARIABLES	{ a3ComSysSystemOvertemperature }
	DESCRIPTION
		"The trap that is generated when the system temperature
		exceeds a certain threshold."
	::= 1

a3ComSysPowerSupplyFailureEvent TRAP-TYPE
	ENTERPRISE	switchingSystemsMibGroups  
	VARIABLES	{ a3ComSysPowerSupplyStatusIndex,
				  a3ComSysPowerSupplyStatus,
				  a3ComSysPowerSupplyStatusSupported }
	DESCRIPTION
		"The trap that is generated when a power supply unit
		fails."
	::= 2

a3ComSysChassisSlotOverTemperatureEvent TRAP-TYPE
	ENTERPRISE  switchingSystemsMibGroups
	VARIABLES   { a3ComSysSlotIndex,
				  a3ComSysSlotBoardType,
				  a3ComSysSlotBoardRevision,
                  a3ComSysSlotBoardStatus,
                  a3ComSysSlotOvertemperature,
                  a3ComSysSlotConverterBad }
    DESCRIPTION
        "The trap that is generated when the temperature of a
         board in a particular slot exceeds a certain threshold."
    ::= 3

a3ComSysChassisSlotInsertEvent TRAP-TYPE
	ENTERPRISE  switchingSystemsMibGroups
    VARIABLES   { a3ComSysSlotIndex,
                  a3ComSysSlotBoardType,
                  a3ComSysSlotBoardRevision }
    DESCRIPTION
        "The trap that is generated when a board is inserted into a
         particular slot."
    ::= 4

a3ComSysChassisSlotExtractEvent TRAP-TYPE
     ENTERPRISE  switchingSystemsMibGroups
     VARIABLES   { a3ComSysSlotIndex }
     DESCRIPTION
         "The trap that is generated when a board is extracted
          from a particular slot."
    ::= 5

a3ComSysBridgeAddressThresholdEvent TRAP-TYPE
	ENTERPRISE	switchingSystemsMibGroups 
	VARIABLES	{ a3ComSysBridgeIndex }
	DESCRIPTION
			"The trap that is generated when the number of addresses
			stored in the bridge reaches a3ComSysBridgeAddressThreshold."
	::= 6

a3ComSysSystemFanFailureEvent TRAP-TYPE
	ENTERPRISE	switchingSystemsMibGroups 
	VARIABLES	{ a3ComSysSystemFanFailure }
	DESCRIPTION
			"The trap that is generated when one of the system fans
			fails."
	::= 7

a3ComSysModuleCardSysOverTemperatureEvent TRAP-TYPE
	ENTERPRISE	switchingSystemsMibGroups 
	VARIABLES	{ a3ComSysModuleCardInfoIndex,
    			  a3ComSysModuleCardInfoFamily,
				  a3ComSysModuleCardInfoGenericType }
	DESCRIPTION
			"The trap that is generated when the temperature of 
			the system exceeds a certain threshold.  This trap is
            generated from agents that support the 
            a3ComSysModuleCardInfoTable."
	::= 8

a3ComSysModuleCardInsertEvent TRAP-TYPE
	ENTERPRISE	switchingSystemsMibGroups 
	VARIABLES	{ a3ComSysModuleCardInfoIndex,
				  a3ComSysModuleCardInfoFamily,
				  a3ComSysModuleCardInfoGenericType,
				  a3ComSysModuleCardInfoSpecificType }
	DESCRIPTION
			"The trap that is generated when a board is inserted into a
			particular modular slot.  This trap is generated from agents 
            that support the a3ComSysModuleCardInfoTable."
	::= 9

a3ComSysModuleCardExtractEvent TRAP-TYPE
	ENTERPRISE	switchingSystemsMibGroups 
	VARIABLES	{ a3ComSysModuleCardInfoIndex}
	DESCRIPTION
			"The trap that is generated when a board is extracted
			from a particular modular slot.  This trap is generated
            from agents that support the a3ComSysModuleCardInfoTable."
	::= 10