-- Copyright (C) 2004 by  HUAWEI TECHNOLOGIES. All rights reserved
-- 
-- Description:This mib file is used for management of huawei Class Based 
--             FR QoS information. 
-- Reference:
-- Version: V1.1
-- History:      
-- 			V1.0 caolei,2004.7.12,publish 
--          V1.1 2004-10-12 updated by gaolong
--               Relocate hwFrQoSMib MODULE-IDENTITY.
-- =================================================================

	A3COM-HUAWEI-FR-QOS-MIB DEFINITIONS ::= BEGIN
 
		IMPORTS
			hwQoS
				FROM A3COM-HUAWEI-OID-MIB
		
			ifIndex			
				FROM RFC1213-MIB
			
			OBJECT-GROUP, MODULE-COMPLIANCE                 
				FROM SNMPv2-CONF
			
			Integer32, Counter32, OBJECT-TYPE, MODULE-IDENTITY                   
				FROM SNMPv2-SMI
			
			TEXTUAL-CONVENTION, RowStatus
				FROM SNMPv2-TC;        

            hwFrQoSMib MODULE-IDENTITY 
                    LAST-UPDATED "200407120000Z"            -- JULY 12, 2004 at 00:00 GMT
                    ORGANIZATION 
                            "Huawei Technologies co.,Ltd."
                    CONTACT-INFO 
                            " R&D BeiJing, Huawei Technologies co.,Ltd.
                            Huawei Bld.,NO.3 Xinxi Rd., 
                            Shang-Di Information Industry Base,
                            Hai-Dian District Beijing P.R. China
                            Zip:100085 
                            Http://www.huawei.com                                       
                            E-mail:support@huawei.com "
                    DESCRIPTION 
                            "This MIB contains objects to 
                            Manage configuration and Monitor running state 
                            for Class Based FR QoS feature.
                            
                           	    *********************************
                        			MIB Tables
                           	    **********************************
                        	This MIB consists of the following tables:
                        	     1 :  hwFrClassCfgInfoTable
                        	     2 :  hwCirCfgInfoTable
                        	     3 :  hwIfApplyFrClassTable
                        	     4 :  hwPvcApplyFrClassTable
                        	     5 :  hwFrPvcBandwidthTable
                        	     5 :  hwRTPFrClassApplyTable
                        	     6 :  hwRTPFrPvcQueueRunInfoTable  	             	 
                            "
                    ::= { hwQoS 3 } -- need modification later

--            
--type definitions in the policy 
--
				
--Direction         
				
			CirAllowDirection ::= TEXTUAL-CONVENTION
			        STATUS  current  
			        DESCRIPTION
			              "The Packet Direction apply on."				 
					SYNTAX  INTEGER { 
						inbound (1),
						outbound (2),
						inboundAndOutbound (3)
					}                  
	
--            
--end of type definitions in policy 
--				 

--
-- Node definitions
--     
	hwFrQoSObjects OBJECT IDENTIFIER ::= { hwFrQoSMib 1 } 
                                                                                                           
--hwFrClassObjects 
		
	hwFrClassObjects OBJECT IDENTIFIER ::= { hwFrQoSObjects 1 } 
		
-- Fr Class Next Index 
	hwFrClassIndexNext OBJECT-TYPE
		SYNTAX Integer32 
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION
			"This object contains an appropriate value to be used for 
			hwFrClassIndex when creating rows in the 
			hwFrClassCfgInfoTable. Begin with 0.
			"                                
		::= { hwFrClassObjects 1 }
		                                                                                         
-- Fr Class               
	hwFrClassCfgInfoTable OBJECT-TYPE
		SYNTAX SEQUENCE OF HwFrClassCfgInfoEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"A table of Fr Class configuration information."
		::= { hwFrClassObjects 2 }

	hwFrClassCfgInfoEntry OBJECT-TYPE
		SYNTAX HwFrClassCfgInfoEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"Fr Class Configuration Information Entry."
		INDEX { hwFrClassIndex }
		::= { hwFrClassCfgInfoTable 1 }
		
	HwFrClassCfgInfoEntry ::=
		SEQUENCE { 
			hwFrClassIndex
				Integer32,
			hwFrClassName
				OCTET STRING,
			hwFrClassRowStatus
				RowStatus
		} 	

		
	hwFrClassIndex OBJECT-TYPE
		SYNTAX Integer32 
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"Index of Fr Class. Begin with 0."
		::= { hwFrClassCfgInfoEntry 1 }
		        
	hwFrClassName OBJECT-TYPE
		SYNTAX OCTET STRING (SIZE (1..31))
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			"Name of Fr Class."
		::= { hwFrClassCfgInfoEntry 2 }                                  
		
	hwFrClassRowStatus OBJECT-TYPE
		SYNTAX RowStatus
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			"RowStatus. Three actions are used: active,
			createAndGo, destroy"
		::= { hwFrClassCfgInfoEntry 3 }

-- Cir Allow on the Fr Class               
	hwCirAllowCfgInfoTable OBJECT-TYPE
		SYNTAX SEQUENCE OF HwCirAllowCfgInfoEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"A table of DCE allowed rate Configuration information."
		::= { hwFrClassObjects 3 }
		
	hwCirAllowCfgInfoEntry OBJECT-TYPE
		SYNTAX HwCirAllowCfgInfoEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"DCE allowed ratee Configuration Information Entry."
		INDEX { hwCirAllowFrClassIndex,
				hwCirAllowDirection}
		::= { hwCirAllowCfgInfoTable 1 }
		
	HwCirAllowCfgInfoEntry ::=
		SEQUENCE { 
			hwCirAllowFrClassIndex
				Integer32,  
			hwCirAllowDirection 
				CirAllowDirection,                                        
			hwCirAllowValue
				Integer32, 
			hwCirAllowRowStatus
				RowStatus
		} 
		
	hwCirAllowFrClassIndex OBJECT-TYPE
		SYNTAX Integer32 
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"Index of Fr Class. Begin with 0.Equal to hwFrClassIndex"
		::= { hwCirAllowCfgInfoEntry 1 }
		        
	hwCirAllowDirection OBJECT-TYPE
		SYNTAX CirAllowDirection     
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"Packet Direction. 		
			inbound (1)
			outbound (2)
			inbound and outbound (3)  
			"
		::= { hwCirAllowCfgInfoEntry 2 }                                  
		
	hwCirAllowValue OBJECT-TYPE
		SYNTAX Integer32(1..45000000) 
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			"DCE allowed rate (value greater than CIR) 
			Unit : Bits per second. 
			Value : <1-45000000> ."
		::= { hwCirAllowCfgInfoEntry 3 } 
		
	hwCirAllowRowStatus OBJECT-TYPE
		SYNTAX RowStatus
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			"RowStatus. Three actions are used: active,
			createAndGo, destroy"
		::= { hwCirAllowCfgInfoEntry 4 }
		                                    
-- Cir on the Fr Class               
	hwCirCfgInfoTable OBJECT-TYPE
		SYNTAX SEQUENCE OF HwCirCfgInfoEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"A table of Committed Information Rate Configuration information."
		::= { hwFrClassObjects 4 }
		
	hwCirCfgInfoEntry OBJECT-TYPE
		SYNTAX HwCirCfgInfoEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"Committed Information Rate Configuration Information Entry."
		INDEX { hwCirFrClassIndex }
		::= { hwCirCfgInfoTable 1 }
		
	HwCirCfgInfoEntry ::=
		SEQUENCE { 
			hwCirFrClassIndex
				Integer32,  
			hwCirValue
				Integer32,		
			hwCirRowStatus
				RowStatus
		} 
		
	hwCirFrClassIndex OBJECT-TYPE
		SYNTAX Integer32 
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"Index of Fr Class. Begin with 0.Equal to hwFrClassIndex"
		::= { hwCirCfgInfoEntry 1 }
		        
	hwCirValue OBJECT-TYPE
		SYNTAX Integer32(1000..45000000)
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			" CIR in packet output direction ,bps. 
			Value : <1000-45000000>."
		::= { hwCirCfgInfoEntry 2 } 
		                               
	hwCirRowStatus OBJECT-TYPE
		SYNTAX RowStatus
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			"RowStatus. Three actions are used: active,
			createAndGo, destroy"
		::= { hwCirCfgInfoEntry 3 }
		
		                                  
-- Fr Class Instance on interface Table
	hwIfApplyFrClassTable OBJECT-TYPE
		SYNTAX SEQUENCE OF HwIfApplyFrClassEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"A table of QoS Fr Class instance."
		::= { hwFrClassObjects 5 }
		
	hwIfApplyFrClassEntry OBJECT-TYPE
		SYNTAX HwIfApplyFrClassEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"FrClass applied on interface Configuration Information Entry."
		INDEX { hwIfApplyFrClassIfIndex }
		::= { hwIfApplyFrClassTable 1 }
		
	HwIfApplyFrClassEntry ::=
			SEQUENCE {        
				hwIfApplyFrClassIfIndex
			Integer32,                                                                                                                                              
				hwIfApplyFrClassIndex
			Integer32,    
				hwIfApplyFrClassRowStatus
			RowStatus                            	                                            
		}    
			                                 
	hwIfApplyFrClassIfIndex OBJECT-TYPE
		SYNTAX Integer32
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"Interface Index, equal to ifIndex."
		::= { hwIfApplyFrClassEntry 1 }    
		
	hwIfApplyFrClassIndex OBJECT-TYPE
		SYNTAX Integer32
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			"Index of Fr Class, equal to hwFrClassIndex"
		::= { hwIfApplyFrClassEntry 2 }    
		
	hwIfApplyFrClassRowStatus OBJECT-TYPE
		SYNTAX RowStatus
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			"RowStatus. Three actions are used: active,
			createAndGo, destroy"
		::= { hwIfApplyFrClassEntry 3 }
		         
-- Fr Class Instance on fr pvc Table                        
	hwPvcApplyFrClassTable OBJECT-TYPE
		SYNTAX SEQUENCE OF HwPvcApplyFrClassEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"A table of QoS Fr Class instance."
		::= { hwFrClassObjects 6 }
		
	hwPvcApplyFrClassEntry OBJECT-TYPE
		SYNTAX HwPvcApplyFrClassEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"Fr Class applied on FR Pvc Configuration Information Entry."
		INDEX { hwPvcApplyFrClassIfIndex, 
			hwPvcApplyFrClassDlciNum 
		}
		::= { hwPvcApplyFrClassTable 1 }
		
	HwPvcApplyFrClassEntry ::=
		SEQUENCE {            
			hwPvcApplyFrClassIfIndex
				Integer32,
			hwPvcApplyFrClassDlciNum
				Integer32,                                                                                                                                        
			hwPvcApplyFrClassIndex
				Integer32,
			hwPvcApplyFrClassRowStatus
				RowStatus                           		                              	                                            
		}    
			                                 
	hwPvcApplyFrClassIfIndex OBJECT-TYPE
		SYNTAX Integer32
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"Fr Interface Index, equal to ifIndex."
		::= { hwPvcApplyFrClassEntry 1 }
		
	hwPvcApplyFrClassDlciNum OBJECT-TYPE
		SYNTAX Integer32 (16..1007)
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"Fr DLCI number."
		::= { hwPvcApplyFrClassEntry 2 }                            
		
	hwPvcApplyFrClassIndex OBJECT-TYPE
		SYNTAX Integer32
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			"Index of Fr Class, equal to hwFrClassIndex"
		::= { hwPvcApplyFrClassEntry 3 }    
		
	hwPvcApplyFrClassRowStatus OBJECT-TYPE
		SYNTAX RowStatus
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			"RowStatus. Three actions are used: active,
			createAndGo, destroy"
		::= { hwPvcApplyFrClassEntry 4 }


-- bandwidth parameter on interface                        
                       
	hwFrPvcBandwidthTable OBJECT-TYPE
		SYNTAX SEQUENCE OF HwFrPvcBandwidthEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"A table of Running statistics for bandwidth.
			"
		::= { hwFrClassObjects 7 }
		
	hwFrPvcBandwidthEntry OBJECT-TYPE
		SYNTAX HwFrPvcBandwidthEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"Bandwidth Running statistics"
		INDEX { hwPvcApplyFrClassIfIndex, 
			hwPvcApplyFrClassDlciNum 
		}

		::= { hwFrPvcBandwidthTable 1 }
		
	HwFrPvcBandwidthEntry ::=
			SEQUENCE {                                                                                                                                                                          
				hwFrPvcBandwidthMaxReservedBW
					Integer32,
				hwFrPvcBandwidthAvailable
					Integer32					                                	                                            
				}    		 		                                                       
					
	hwFrPvcBandwidthMaxReservedBW OBJECT-TYPE
		SYNTAX Integer32
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION
			"Max reserved bandWidth. Unit : Kbps"
		::= { hwFrPvcBandwidthEntry 1 }	
		
	hwFrPvcBandwidthAvailable OBJECT-TYPE
		SYNTAX Integer32
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION
			"Available bandWidth. Unit : Kbps"
		::= { hwFrPvcBandwidthEntry 2 }  			
		
                                                                                                       
--hwRTPQoSObjects 
		
	hwRTPQoSObjects OBJECT IDENTIFIER ::= { hwFrQoSObjects 2 } 
		
-- Rtpq applied on the Fr Class 
		
	hwRTPFrClassApplyTable OBJECT-TYPE
		SYNTAX SEQUENCE OF HwRTPFrClassApplyEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"A table of RTP(Realtime Transport Protocol) Queue instance."
		::= { hwRTPQoSObjects 1 }
		
	hwRTPFrClassApplyEntry OBJECT-TYPE
		SYNTAX HwRTPFrClassApplyEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"RTP(Realtime Transport Protocol) Queue Configuration Information Entry."
		INDEX { hwRTPFrClassApplyFrClassIndex }
		::= { hwRTPFrClassApplyTable 1 }
		
	HwRTPFrClassApplyEntry ::=
		SEQUENCE { 
			hwRTPFrClassApplyFrClassIndex
				Integer32,
			hwRTPFrClassApplyStartPort
				Integer32,
			hwRTPFrClassApplyEndPort 
				Integer32,
			hwRTPFrClassApplyBandWidth 
				Integer32,
			hwRTPFrClassApplyCbs 
				Integer32,				
			hwRTPFrClassApplyRowStatus 
				RowStatus                               		 
		}  
		
	hwRTPFrClassApplyFrClassIndex OBJECT-TYPE
		SYNTAX Integer32
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"Fr Class Index, equal to HwFrClassIndex."
		::= { hwRTPFrClassApplyEntry 1 }    
		
	hwRTPFrClassApplyStartPort OBJECT-TYPE
		SYNTAX Integer32(2000..65535)
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			"                                                                                        
			RTP-PORT(3): start-port: 2000~65535   
			"                         
		::= { hwRTPFrClassApplyEntry 2 }
		
	hwRTPFrClassApplyEndPort OBJECT-TYPE
		SYNTAX Integer32(2000..65535)
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			"                         
			RTP-PORT(3): end-port: 2000~65535
			"                         
		::= { hwRTPFrClassApplyEntry 3 }
		
	hwRTPFrClassApplyBandWidth OBJECT-TYPE
		SYNTAX Integer32 (8..1000000)
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			"Max bandWidth Value:
			Absolute value: 8~1000000. Unit: Kbps             
			"                
		::= { hwRTPFrClassApplyEntry 4 }  
		
	hwRTPFrClassApplyCbs OBJECT-TYPE
		SYNTAX Integer32 (1500..2000000)
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			"
			Committed Burst Size: 1500~2000000. Unit: byte             
			"                
		::= { hwRTPFrClassApplyEntry 5 }  		
		
	hwRTPFrClassApplyRowStatus OBJECT-TYPE
		SYNTAX RowStatus
		MAX-ACCESS read-create
		STATUS current
		DESCRIPTION
			"RowStatus for RTPFrClassApply Table. 
			Three actions are used: active, createAndGo, destroy"
		::= { hwRTPFrClassApplyEntry 6 } 

-- RTPQ statistics on the Fr Pvc 
		                 
	hwRTPFrPvcQueueRunInfoTable OBJECT-TYPE
		SYNTAX SEQUENCE OF HwRTPFrPvcQueueRunInfoEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"A table of Running statistics for RTP(Realtime Transport Protocol) Queue
			applied on the FR PVC"
		::= { hwRTPQoSObjects 2 }
		
	hwRTPFrPvcQueueRunInfoEntry OBJECT-TYPE
		SYNTAX HwRTPFrPvcQueueRunInfoEntry
		MAX-ACCESS not-accessible
		STATUS current
		DESCRIPTION
			"RTP(Realtime Transport Protocol) Queue statistics entry."
		INDEX { hwPvcApplyFrClassIfIndex,                        		
			hwPvcApplyFrClassDlciNum                      	    
		}
		::= { hwRTPFrPvcQueueRunInfoTable 1 }
		
	HwRTPFrPvcQueueRunInfoEntry ::=
		SEQUENCE {
			hwRTPFrPvcQueueSize
				Integer32,
			hwRTPFrPvcQueueMaxSize
				Integer32, 
			hwRTPFrPvcQueueOutputs
				Counter32,
			hwRTPFrPvcQueueDiscards
				Counter32                                                                                                                                                                                                                                    
		}  
		    
	hwRTPFrPvcQueueSize OBJECT-TYPE
		SYNTAX Integer32
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION
			"the packet number of RTP(Realtime Transport Protocol) Queue now."
		::= { hwRTPFrPvcQueueRunInfoEntry 1 }    
		    		         
	hwRTPFrPvcQueueMaxSize OBJECT-TYPE
		SYNTAX Integer32
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION
			"the Max packet number of RTP(Realtime Transport Protocol) Queue."
		::= { hwRTPFrPvcQueueRunInfoEntry 2 }
		
	hwRTPFrPvcQueueOutputs OBJECT-TYPE
		SYNTAX Counter32
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION
			"the Output packet number of RTP(Realtime Transport Protocol) Queue."
		::= { hwRTPFrPvcQueueRunInfoEntry 3 } 
		         
	hwRTPFrPvcQueueDiscards OBJECT-TYPE
		SYNTAX Counter32
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION
			"the Discarded packet number of RTP(Realtime Transport Protocol) Queue."
		::= { hwRTPFrPvcQueueRunInfoEntry 4 }
											        