-- Copyright (c) 2004-2012 Hangzhou H3C Tech. Co., Ltd. All rights reserved.
--
-- Description:This file describes various common MIB objects implemented by both
--             Routers and Switches for use.
-- Reference:
-- Version: V2.3
-- History:
-- V1.0 26th Nov 2003
--      Separated from a3Comm8040.mib
-- V1.1 9th Dec 2003
--      a3comoemrouter.mib added
-- V1.2 23rd Jan 2004
--      merged in common node defns from a3Comoemrouter.mib
-- V1.3 24th Feb 2004
--      module imported from A3COM-HUAWEI-OID-MIB which is the root MIB MODULE for huawei-3com.
--      delete MODULE-IDENTITY import declaration
-- V1.4 16th Aug 2004
--      Add a trap node 'hwRebootSendTrap' into hwSystemNotification
-- V2.0 2004-10-12 updated by gaolong
--      Import from SNMPv2-SMI and SNMPv2-TC instead from RFC1212 and RFC1155-SMI
--      Change ACCESS clauses to MAX-ACCESS
--      Change STATUS clauses from mandatory to current
-- V2.1 2008-11-11 add node hwSysBootType by lifengguang
-- V2.2 2009-05-05 add hwSysStatisticPeriod, hwSysSamplePeriod,
--      hwSysTrapResendPeriod, hwSysTrapCollectionPeriod, hwSysColdStartTrap,
--      hwSysWarmStartTrap, hwSysSnmpPort, hwSysSnmpTrapPort, hwSysNetID,
--      hwSysLastSampleTime by jinyi
-- V2.3 2012-01-07 add node hwSysTrapSendNum and hwSysFirstTrapTime by duyanbing
-- =========================================================================
A3COM-HUAWEI-COMMON-MIB DEFINITIONS ::= BEGIN

    IMPORTS
        OBJECT-TYPE, NOTIFICATION-TYPE, TimeTicks
            FROM SNMPv2-SMI
        DisplayString, DateAndTime
            FROM SNMPv2-TC
        hwSystem
            FROM A3COM-HUAWEI-OID-MIB;

-- ==============================
-- Begin define of hwmHostName
-- ==============================

    hwWriteConfig OBJECT-TYPE
        SYNTAX INTEGER{
                       save(1)
                      }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "Write config to router."
        ::= { hwSystem 5 }

    hwStartFtpServer OBJECT-TYPE
        SYNTAX INTEGER{
                       enable(1),
                       disable(2)
                       }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "Decide whether start ftp-server.enable(1) indicates to start ftp-server;
            disable(2) indicates to stop ftp-server."
        ::= { hwSystem 6 }

    hwReboot OBJECT-TYPE
        SYNTAX INTEGER{
                       reboot(1)
                       }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "Reboot router."
        ::= { hwSystem 7 }

    hwSystemNotification OBJECT IDENTIFIER ::= { hwSystem 8 }

    hwWriteSuccessTrap NOTIFICATION-TYPE
        STATUS current
        DESCRIPTION
            "send a trap about write success."
        ::= { hwSystemNotification 1 }

    hwWriteFailureTrap NOTIFICATION-TYPE
        STATUS current
        DESCRIPTION
            "send a trap about write failure."
        ::= { hwSystemNotification 2 }

    hwRebootSendTrap NOTIFICATION-TYPE
        STATUS current
        DESCRIPTION
            "When users restart the device with command
            'reboot', this trap will be sent two seconds
             before the device reboots."
        ::= { hwSystemNotification 3 }

    hwSysColdStartTrap NOTIFICATION-TYPE
        OBJECTS
            {
                hwSysFirstTrapTime
            }
        STATUS current
        DESCRIPTION
            "A system cold start trap."
        ::= { hwSystemNotification 4 }

    hwSysWarmStartTrap NOTIFICATION-TYPE
        OBJECTS
            {
                hwSysFirstTrapTime
            }
        STATUS current
        DESCRIPTION
            "A system warm start trap."
        ::= { hwSystemNotification 5 }

    hwSoftwareVersion OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Software version."
        ::= { hwSystem 9 }

    hwSysBootType OBJECT-TYPE
        SYNTAX INTEGER
        {
            coldStart(1),           -- Cold start
            warmStart(2)            -- Warm start
        }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The boot type of the system whether the last device reboot was by
            CLI (warm start) or power off (cold start)."
        ::= { hwSystem 10 }

    hwSystemInfo OBJECT IDENTIFIER ::= { hwSystem 11 }

    hwSysStatisticPeriod OBJECT-TYPE
        SYNTAX      INTEGER(0..900)
        UNITS       "seconds"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The statistic period. The device collects statistics
             within the period."
        DEFVAL { 0 }
        ::= { hwSystemInfo 1 }

    hwSysSamplePeriod OBJECT-TYPE
        SYNTAX      INTEGER(0..300)
        UNITS       "seconds"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The sampling period. The device takes samples periodically
             for statistics collection."
        DEFVAL { 0 }
        ::= { hwSystemInfo 2 }

    hwSysTrapResendPeriod OBJECT-TYPE
        SYNTAX      INTEGER(0..3600)
        UNITS       "seconds"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The trap resending period. If the value is zero, the trap
             will not be re-sent."
        DEFVAL { 0 }
        ::= { hwSystemInfo 3 }

    hwSysTrapCollectionPeriod OBJECT-TYPE
        SYNTAX      INTEGER(0..60)
        UNITS       "seconds"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The trap collecting period. If the value is zero, the trap
             will not be re-sent."
        DEFVAL { 0 }
        ::= { hwSystemInfo 4 }

    hwSysSnmpPort OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "UDP port for SNMP protocol entity to receive messages except Trap-PDU."
        ::= { hwSystemInfo 5 }

    hwSysSnmpTrapPort OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "UDP port for Trap-PDU to receive messages."
        ::= { hwSystemInfo 6 }

    hwSysNetID OBJECT-TYPE
        SYNTAX      OCTET STRING(SIZE(0..127))
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The system Net ID."
        ::= { hwSystemInfo 7 }

    hwSysLastSampleTime OBJECT-TYPE
        SYNTAX      DateAndTime
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The last sample local time of the system."
        ::= { hwSystemInfo 8 }

    hwSysTrapSendNum OBJECT-TYPE
        SYNTAX      INTEGER(0..24)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The trap send times. If the value is zero, the trap
             will be sent all the time if it occurs."
        ::= { hwSystemInfo 9 }

    hwSysFirstTrapTime OBJECT-TYPE
        SYNTAX      TimeTicks
        MAX-ACCESS  accessible-for-notify
        STATUS      current
        DESCRIPTION
            "Represents the first trap time."
        ::= { hwSystemInfo 10 }

END